2012
DOI: 10.1111/nmo.12054
|View full text |Cite
|
Sign up to set email alerts
|

Comprehensive assessment of gastric emptying with a stable isotope breath test

Abstract: Background The [13C]-Spirulina platensis gastric emptying breath test (GEBT) with 5 samples is accurate relative to scintigraphy. This study was primarily designed to further validate this GEBT using a slightly different process for incorporating [13C] in Spirulina and to evaluate the utility of additional samples for assessing early gastric emptying. Methods After a 223 kcal test meal labeled with 99mTc and [13C]-Spirulina platensis, scintigraphic images and 5 breath samples (45, 90, 120, 180, and 240 minut… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
54
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 62 publications
(61 citation statements)
references
References 28 publications
2
54
0
1
Order By: Relevance
“…The GEBT has been extensively used and validated against scintigraphy in health and disease, including in participants with DM. 24, 25 The intra- and inter-individual variability are comparable to that for scintigraphy. 25 In addition, this GEBT has been used in over 2000 patients in Phase I and Phase II pharmaceutical investigations of pro-kinetic drugs under sponsors’ IND exemptions (personal communication, AB Diagnostics), some of which have been published.…”
Section: Methodsmentioning
confidence: 61%
See 1 more Smart Citation
“…The GEBT has been extensively used and validated against scintigraphy in health and disease, including in participants with DM. 24, 25 The intra- and inter-individual variability are comparable to that for scintigraphy. 25 In addition, this GEBT has been used in over 2000 patients in Phase I and Phase II pharmaceutical investigations of pro-kinetic drugs under sponsors’ IND exemptions (personal communication, AB Diagnostics), some of which have been published.…”
Section: Methodsmentioning
confidence: 61%
“…28 The 13C excretion was used to estimate GE T ½ using validated models derived from studies in which GE was simultaneously assessed by the 13C-Spirulina platensis breath test and scintigraphy. 24, 25 For the meal employed, the 10th–90th percentile range for GE T ½ in healthy subjects is 50–92 minutes. 25 Hence, values less than 50 and greater than 92 minutes reflect rapid and delayed GE, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…These units were used to estimate GE t half using validated models derived from studies in which GE was simultaneously assessed by the 13 C- Spirulina platensis breath test and scintigraphy. 20, 21 For this meal, the 10 th –90 th percentile range for GE t half in healthy subjects is 50–97 minutes. 20 …”
Section: Methodsmentioning
confidence: 91%
“…20, 21 For this meal, the 10 th –90 th percentile range for GE t half in healthy subjects is 50–97 minutes. 20 …”
Section: Methodsmentioning
confidence: 91%
“…Gastric emptying breath tests utilize 13 C, which is a stable isotope, and offer an alternative approach for measuring solid phase GE without elaborate detection equipment or radiation exposure in the office or bedside. 12, 13 The Food and Drug Administration is currently reviewing a 13 C-spirulina GEBT for use in the United States. Gastric emptying can also be measured by a nondigestible capsule, SmartPill ™ , which records luminal pH, temperature, and pressure during GI transit providing a measure of GE time.…”
Section: Prevalence and Incidencementioning
confidence: 99%