2022
DOI: 10.1039/d2ra02831j
|View full text |Cite
|
Sign up to set email alerts
|

Compound green tea (CGT) regulates lipid metabolism in high-fat diet induced mice

Abstract: Compound green tea is able to decrease the body weight and regulate the plasma lipid indexes, as well as make the abnormal metabolic state return to normal by intervening in different metabolic pathways to partially reverse the lipid metabolism disorder.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 42 publications
0
4
0
Order By: Relevance
“…The extract was analyzed using a UPLC-ESI-MS/MS system (UPLC, SHI-MADZU Nexera X2, https://www.shimadzu.com.cn/, accessed on 9 November 2021; MS, Applied Biosystems 4500 Q TRAP, https:// www.thermofisher.cn/cn/zh/home/brands/applied-biosystems.html, accessed on 9 November 2021) with the analytical conditions described by Zhou et al (2022). The effluent was alternately connected to the ESI-triple quadrupole-linear ion trap (QTRAP)-MS.…”
Section: Uplc and Esi-q Trap-ms/ms Conditionsmentioning
confidence: 99%
See 1 more Smart Citation
“…The extract was analyzed using a UPLC-ESI-MS/MS system (UPLC, SHI-MADZU Nexera X2, https://www.shimadzu.com.cn/, accessed on 9 November 2021; MS, Applied Biosystems 4500 Q TRAP, https:// www.thermofisher.cn/cn/zh/home/brands/applied-biosystems.html, accessed on 9 November 2021) with the analytical conditions described by Zhou et al (2022). The effluent was alternately connected to the ESI-triple quadrupole-linear ion trap (QTRAP)-MS.…”
Section: Uplc and Esi-q Trap-ms/ms Conditionsmentioning
confidence: 99%
“…The ion spray voltage (IS) was set to 5500 V and À 4500 V in positive and negative ion modes. Other ESI source operation parameters were the same as the Zhou et al (2022) protocol.…”
Section: Uplc and Esi-q Trap-ms/ms Conditionsmentioning
confidence: 99%
“…Analysis of extract was performed using an UPLC-ESI-MS/MS system (UPLC, SHIMADZU Nexera X2, https://www.shimadzu.com.cn/, accessed on 9 November 2021; MS, Applied Biosystems 4500 Q TRAP, https://www.thermo sher.cn/cn/zh/home/brands/applied-biosystems.html, accessed on 9 November 2021) with the analytical conditions following the method described by Zhou et al [15]. The e uent was alternately connected to ESI-triple quadrupole-linear ion trap (QTRAP)-MS.…”
Section: Uplc and Esi-q Trap-ms/ms Conditionsmentioning
confidence: 99%
“…The ion spray voltage (IS) was set to 5500 V and − 4500 V in positive and negative ion modes. And other ESI source operation parameters were same as the protocol [15].…”
Section: Uplc and Esi-q Trap-ms/ms Conditionsmentioning
confidence: 99%