2010
DOI: 10.1134/s1070427210120098
|View full text |Cite
|
Sign up to set email alerts
|

Composite sorbents for recovery of cesium radionuclides

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2011
2011
2017
2017

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 1 publication
0
4
0
Order By: Relevance
“…Hexacyanoferrate-based sorbents are mainly oriented toward the recovery of Cs(I) [1,7,8,12,17,22,23,27,30,31,32,33,34,36,37,38,43,45,46,47,51,52,53,55,56,57,58,62,63,65,67,68,69,70,71,74,75,77,78,79,80,81,83,86,87,89,92,93,94,96,98,99,100,103,108,109,110,111,112,113,114,115,116,117,118,119,120,…”
Section: Synthesis and Sorption Properties Of Bulk Hexacyanoferratmentioning
confidence: 99%
See 1 more Smart Citation
“…Hexacyanoferrate-based sorbents are mainly oriented toward the recovery of Cs(I) [1,7,8,12,17,22,23,27,30,31,32,33,34,36,37,38,43,45,46,47,51,52,53,55,56,57,58,62,63,65,67,68,69,70,71,74,75,77,78,79,80,81,83,86,87,89,92,93,94,96,98,99,100,103,108,109,110,111,112,113,114,115,116,117,118,119,120,…”
Section: Synthesis and Sorption Properties Of Bulk Hexacyanoferratmentioning
confidence: 99%
“…Sheveleva et al [117,118] reported the deposition of a Co,Ni-hexacyanoferrate/siloxane-acrylate emulsion at the surface of activated carbon fibers. The siloxane-acrylate emulsion was mixed, for several successive steps, with cobalt and nickel chloride solutions and with potassium hexacyanoferrate.…”
Section: Techniques For Immobilization Of Metal Hexacyanoferratesmentioning
confidence: 99%
“…Fig. 9 shows that with increase of anode potential during latexes deposition from +0.3 V to +0.9 V the thickness of the film abruptly increases, most likely, due to the aggregation of latex particles in solution at potential +0.7 V and +0.9 V [22]. Since the content of ferrocyanide in composite materials directly depends on the amount of latex deposited, the highest ferrocyanide loading degrees were obtained at polarization +0.9 V (Table 3).…”
Section: Carbon Fiber Composites Containing Functionalized Latex Partmentioning
confidence: 96%
“…Also, because adsorption is sometimes reversible, adsorbents can be regenerated. Transition metal (Ni, Zn, Cu, Fe, Co) hexacyanoferrates (MHCFs) are of the most frequently applied adsorbents for the treatment of radiocaesium wastewaters due to the high affinity for caesium ions and other radionuclides [11].…”
mentioning
confidence: 99%