2020
DOI: 10.3390/ma13081832
|View full text |Cite
|
Sign up to set email alerts
|

Composite Heat Sink Material for Superconducting Tape in Fault Current Limiter Applications

Abstract: We enhanced the performance of superconducting tapes during quenching by coating the tapes with various composites, with regards to the application of such coated systems in superconducting fault current limiters. In composition of the coating, we varied the type of epoxy matrix, the content of ceramic filler particles and the use of reinforcement in order to optimize the thermal and the mechanical stability of the coated tapes. By this way modified superconducting tapes were able to reduce the maximum tempera… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 12 publications
(13 citation statements)
references
References 34 publications
(35 reference statements)
1
11
0
Order By: Relevance
“…After reaching the temperature of glass transition, the increasing trend continues, however, with a higher slope. These measurements showed that higher SiC content results in a mild shifting of T g to lower values (see Figure 2) [24].…”
Section: Thermophysical Propertiesmentioning
confidence: 91%
See 3 more Smart Citations
“…After reaching the temperature of glass transition, the increasing trend continues, however, with a higher slope. These measurements showed that higher SiC content results in a mild shifting of T g to lower values (see Figure 2) [24].…”
Section: Thermophysical Propertiesmentioning
confidence: 91%
“…The CTE in the temperature range from −200 • C to 200 • C for all composite systems was determined on the base of our previous study [24] and is depicted in Figure 2. The CTE of SB11 was supplemented to −200 • C according to Swenson et al [27].…”
Section: Thermophysical Propertiesmentioning
confidence: 99%
See 2 more Smart Citations
“…The curing time at 25 °C is 16–24 h for both catalysts, whereas the pot life is larger for the latter (60 vs. 45 min). This epoxy has a thermal conductivity ĸ ep ≈ 1 W m −1 K −1 at room temperature (RT) [ 21 ], which decreases to ≈0.64 W m −1 K −1 at T = 70 K [ 22 ]. Commercial copper plates (from Sanmetal, Zaragoza, Spain) of 99.9% purity and average roughness of 0.45 ± 0.11 μm were used.…”
Section: Methodsmentioning
confidence: 99%