Abstract: Abstract. A noninvasive head probe that combines near-infrared spectroscopy (NIRS) and electroencephalography (EEG) for simultaneous measurement of neural dynamics and hemodynamics in the brain is presented. It is composed of a compliant expandable mechanism that accommodates a wide range of head size variation and an elastomeric web that maintains uniform sensor contact pressure on the scalp as the mechanism expands and contracts. The design is intended to help maximize optical and electrical coupling and to … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2014
2014
2018
2018

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 18 publications
(16 citation statements)
references
References 53 publications
0
16
0
Order By: Relevance
“…Digitization methods (He and Estepp, 2013) and custom electrode designs (Koessler et al, 2008) are often used to translate the locations of measurement from the subject to the software analysis tools and methods. Head probes and caps can also be used to provide accurate and precise positioning of electrodes in a fast and convenient way (Giacometti and Diamond, 2013). However, the need for localization of scalp coordinates is still necessary for EEG data analysis.…”
Section: Discussionmentioning
confidence: 99%
“…Digitization methods (He and Estepp, 2013) and custom electrode designs (Koessler et al, 2008) are often used to translate the locations of measurement from the subject to the software analysis tools and methods. Head probes and caps can also be used to provide accurate and precise positioning of electrodes in a fast and convenient way (Giacometti and Diamond, 2013). However, the need for localization of scalp coordinates is still necessary for EEG data analysis.…”
Section: Discussionmentioning
confidence: 99%
“…Technical progress has also made it possible to combine EEG with functional NIRS (fNIRS), another non-invasive method. This method, we refer to as EEG+fNIRS, yields similar measurements with lower space but higher time resolution, in a far more practical and cost-effective arrangement (Buccino et al, 2016;Giacometti and Diamond, 2013;Keles et al, 2014;Koch et al, 2006Koch et al, , 2008Koch et al, , 2009Roche-Labarbe et al, 2008;Safaie et al, 2013). The utility of fNIRS as an independent modality for investigating the adult brain hemodynamics (Gentili et al, 2013;Mesquita et al, 2010;White et al, 2009) as well as infant development (Lloyd-Fox et al, 2010) is already well established.…”
Section: Introductionmentioning
confidence: 99%
“…The positions chosen follow the layout of the NIRS–EEG head probe developed by our lab. 50 The source-detector pairs chosen have a mean separation distance of 42.30 ± 7.48 mm, as shown in Fig. 2.…”
Section: Methodsmentioning
confidence: 99%
“…A subset of 65 EEG electrode positions, corresponding to the 10-10 positioning layout, was chosen from the 329 positions for displaying the tabulated results in order to follow the layout of the NIRS-EEG head probe we use in our lab. 50 The electrodes selected for Table 2 are indicated in Fig. 1.…”
Section: Methodsmentioning
confidence: 99%