2006
DOI: 10.1590/s0103-50532006000200014
|View full text |Cite
|
Sign up to set email alerts
|

Complexometric determination of thallium(III) using ethanethiol as a selective masking agent

Abstract: Um método complexométrico simples e seletivo é proposto para a determinação de tálio na presença de outros metais, pela habilidade do etanetiol em mascarar seletivamente íons tálio (III). Em solução, o tálio presente foi inicialmente complexado com um excesso conhecido de EDTA, sendo o excesso titulado com uma solução padrão de sulfato de zinco em pH 5-6 (hexamina), usando-se xilenol como indicador. Uma solução aquosa de etanetiol 0,3 % foi então adicionada para deslocar o EDTA do complexo Tl(III)-EDTA. O EDTA… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2007
2007
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 6 publications
0
9
0
Order By: Relevance
“…The ligand (0.002 M) was mixed with Scheme 1. Structure of (a) the enol form of 2-thiobarbituric acid; (b) Ca 2 (H 2 O) 8 …”
Section: Materials and Synthesismentioning
confidence: 99%
See 1 more Smart Citation
“…The ligand (0.002 M) was mixed with Scheme 1. Structure of (a) the enol form of 2-thiobarbituric acid; (b) Ca 2 (H 2 O) 8 …”
Section: Materials and Synthesismentioning
confidence: 99%
“…2-thiobarbituric acid (2-thioxodihydropyrimidine-4,6(1H,5H)-dione, H 2 TBA) (scheme 1(a)) has important applications in pharmaceuticals and analytical chemistry [7][8][9]. It has many possible tautomeric structures [10,11] and very desirable properties for forming supramolecular structures [3].…”
Section: Introductionmentioning
confidence: 99%
“…The masking agents for Pd have been summarized in previous studies [26][27]. The typical reagents are thiourea and ethylenediamine, which include soft N-or S-donor atoms.…”
Section: Masking Effect On Pdmentioning
confidence: 99%
“…1,2 Thus, thallium poisoning is recognized as an industrial hazard and its monitoring in different matrices have drawn the attention of researchers. [3][4][5][6] The extremely low concentration of thallium in environmental sample (down to ng L -1 level) requires an analytical method featuring high sensitivity and a low detection limit. Thallium had been determined by inductively coupled plasma mass spectrometry (ICP-MS) [6][7][8] and laser-excited atomic fluorescence spectrometry (LEAFS).…”
Section: Introductionmentioning
confidence: 99%
“…[3][4][5][6] The extremely low concentration of thallium in environmental sample (down to ng L -1 level) requires an analytical method featuring high sensitivity and a low detection limit. Thallium had been determined by inductively coupled plasma mass spectrometry (ICP-MS) [6][7][8] and laser-excited atomic fluorescence spectrometry (LEAFS). 9 However, ICP-MS is an expensive analytical method and incurs high running cost, and LEAFS is less frequently used.…”
Section: Introductionmentioning
confidence: 99%