2020
DOI: 10.1016/j.ijrobp.2019.09.003
|View full text |Cite
|
Sign up to set email alerts
|

Complexity in Radiation Therapy: It's Complicated

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
15
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(20 citation statements)
references
References 28 publications
(37 reference statements)
0
15
0
1
Order By: Relevance
“…the aperture shape controller (ASC) tool in the Eclipse TPS [94] and the modulation factor (MF) in the TomoTherapy Hi-Art treatment system [95][96][97], but most TPSs still do not directly incorporate advanced complexity metrics [77]. Thus, unnecessary plan complexity is sometimes a consequence of inverse planning and better tools are needed to handle plan complexity [98]. To that aim, we encourage TPS manufacturers to: Minimise and better control plan complexity by incorporating complexity metrics into the optimisation algorithms.…”
Section: Plan Complexitymentioning
confidence: 99%
“…the aperture shape controller (ASC) tool in the Eclipse TPS [94] and the modulation factor (MF) in the TomoTherapy Hi-Art treatment system [95][96][97], but most TPSs still do not directly incorporate advanced complexity metrics [77]. Thus, unnecessary plan complexity is sometimes a consequence of inverse planning and better tools are needed to handle plan complexity [98]. To that aim, we encourage TPS manufacturers to: Minimise and better control plan complexity by incorporating complexity metrics into the optimisation algorithms.…”
Section: Plan Complexitymentioning
confidence: 99%
“…are used to demonstrate that plans generated with a novel planning technique are not more complex than those from another conventional planning approach. However, there is a lack of agreement on the general applicability of proposed plan complexity parameters in terms of prediction of plan deliverability [19]. 41.…”
Section: Plan Deliverability and Complexitymentioning
confidence: 99%
“…Over the past few decades, radiation treatment delivery techniques have been improving. The introductions of intensity‐modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) have provided a more conformal dose coverage to the target volumes while sparing the normal tissue and nearby organs at risk (OARs) 1,2 . VMAT provides a conformal dose to the targets and OARs through the modulation of the beam.…”
Section: Introductionmentioning
confidence: 99%