1997
DOI: 10.1016/s0003-2670(97)00074-3
|View full text |Cite
|
Sign up to set email alerts
|

Complex formation of 2-(5-nitro-2-pyridylazo)-5-(N-propyl-N-sulfo-propylamino) phenol with lead, cadmium and manganese for their sensitive spectrophotometric detection in flow injection and ion chromatography systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
8
0

Year Published

1998
1998
2011
2011

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 21 publications
(8 citation statements)
references
References 14 publications
0
8
0
Order By: Relevance
“…New reagents, which are derivatives of PAR, like 2-[(5-bromo-2-pyridyl)-azo]-5-diethylaminophenol (5-Br-PADAP) and 2-(5-nitro-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino)phenol (Nitro-PAPS) have higher molar absorptivities, approximately 8610 4 and 1.2610 5 L N mol -1 N cm -1 , respectively and could be potentially more suitable in future. They have been used in PCR detection [64,65] and a significant improvement in sensitivity of detection was noted as shown in Fig. 6, but the relatively low solubility of 5-Br-PADAP and high cost of Nitro-PAPS still restrict the wide use of these reagents.…”
Section: New Reagents For Pcrmentioning
confidence: 99%
See 1 more Smart Citation
“…New reagents, which are derivatives of PAR, like 2-[(5-bromo-2-pyridyl)-azo]-5-diethylaminophenol (5-Br-PADAP) and 2-(5-nitro-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino)phenol (Nitro-PAPS) have higher molar absorptivities, approximately 8610 4 and 1.2610 5 L N mol -1 N cm -1 , respectively and could be potentially more suitable in future. They have been used in PCR detection [64,65] and a significant improvement in sensitivity of detection was noted as shown in Fig. 6, but the relatively low solubility of 5-Br-PADAP and high cost of Nitro-PAPS still restrict the wide use of these reagents.…”
Section: New Reagents For Pcrmentioning
confidence: 99%
“…6, but the relatively low solubility of 5-Br-PADAP and high cost of Nitro-PAPS still restrict the wide use of these reagents. Potentially, even more sensitive reagents could be the porphyrins, e. g., meso-tetrakis(4-N-trimethylaminophenyl)porphine (TTMAPP), which gives molar extinction coefficients for the copper complex of 4.8610 5 L N mol -1 N cm -1 [65]; however, the first attempt of their…”
Section: New Reagents For Pcrmentioning
confidence: 99%
“…7 For lead and cadmium determination, the complex formation with 2-(5-nitro-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino)phenol and FI-ion chromatography systems were used; the detection limits were 4.8 μg L -1 for lead and 1.9 μg L -1 for cadmium. 8 Spectrophotometry gives lower running cost. However, its sensitivity is not sufficient for trace analysis.…”
Section: Introductionmentioning
confidence: 99%
“…For such measurements, many methods have been developed. 3 Among all of these, spectrophotometry 4,5 and atomic absorption spectroscopy 6,7 were the routine methods. These methods often suffer from a variety of disadvantages: they could be sophisticated or time-consuming, they could lack enough sensitivity, or they could require expensive instrument.…”
Section: Introductionmentioning
confidence: 99%