1997
DOI: 10.1063/1.1148178
|View full text |Cite
|
Sign up to set email alerts
|

Complete high-frequency measurement of Mueller matrices based on a new coupled-phase modulator

Abstract: A new polarization modulator is presented. It uses two phase-locked identical electro-optic phase modulators at 50 kHz. Thanks to a coupling object introduced between the two phase modulators, the four Stokes parameters of the light beam are independently modulated on the basis of the first and second complex harmonics of the modulation signal. A Mueller matrix ellipsometer (MME) using this new modulation and a multichannel polarimeter are also described. The data processing and the feedback control of Pockels… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2000
2000
2018
2018

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 38 publications
(17 citation statements)
references
References 34 publications
0
17
0
Order By: Relevance
“…Several methods have been proposed to study error propagation, including matrix condition number [28] and efficiency [29]. Efficiency is a four vector defined as…”
Section: Introductionmentioning
confidence: 99%
“…Several methods have been proposed to study error propagation, including matrix condition number [28] and efficiency [29]. Efficiency is a four vector defined as…”
Section: Introductionmentioning
confidence: 99%
“…It can be seen that the basic principle of our device lies in the modulation of the incident polarization state which was first developed by Hunt and Huffman in the design of Angle-Scanning Polarization-Modulation Nephelometer [10]. Based on this electro-optical polarization modulation technique, many instruments have been developed [11,12,13]. The difference between our setup and others similar setup lies in the combination of modulation technique with multichannel polarization state detector.…”
Section: The Setupmentioning
confidence: 88%
“…Finally, the 16 successive measurements for the 16 combinations of PSG and PSA require 16 × ð10 × 200 μsÞ ¼ 32 ms. To reduce the measurement time, liquid crystal cells should be replaced by faster devices. The modulation may be performed with a fast electro-optic 24 or photo-elastic modulator, 25 at the price of increased complexity in instrumentation and signal processing. Polarimeters based on photo-elastic modulators have recently shown the ability to perform Mueller matrix in the millisecond range, 26 i.e., an improvement by a factor of 30 compared to our device.…”
Section: Discussionmentioning