2008
DOI: 10.1364/josab.25.001738
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Z-scan and THG derived nonlinear index of refraction in selected organic solvents

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
37
2
3

Year Published

2008
2008
2024
2024

Publication Types

Select...
5
2
1

Relationship

2
6

Authors

Journals

citations
Cited by 77 publications
(43 citation statements)
references
References 27 publications
1
37
2
3
Order By: Relevance
“…By our results, chloroform has somewhat stronger orientational nonlinearity in comparison with acetone, which is in agreement with Rau et al 58 In the case of DMSO, it seems that this solvent has no significant orientational nonlinearity for the pulse widths we have used here.…”
Section: Resultssupporting
confidence: 93%
See 2 more Smart Citations
“…By our results, chloroform has somewhat stronger orientational nonlinearity in comparison with acetone, which is in agreement with Rau et al 58 In the case of DMSO, it seems that this solvent has no significant orientational nonlinearity for the pulse widths we have used here.…”
Section: Resultssupporting
confidence: 93%
“…58 For a positive nonlinearity, as is usual for the instantaneous electronic polarization of optical glasses, the refractive index is larger at the center of the laser beam than at its periphery, resulting in a positive lens whose focal length depends on the laser irradiance and sample nonlinearity. 59 In In order to verify the validity of the model proposed, we carried out THG Z-scan measurements using a commercial optical parametric amplifier (OPA) (TOPAS, from Light Conversion), synchronously pumped by a chirped-pulse-amplified system (CPA 2001-Clark MXR) with a 775 nm central wavelength and 150 fs pulse duration at 1 kHz repetition rate.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…[15] (see also Rau et al [16]). The excitation is provided by a linearly polarized mode-locked Nd:YAG laser, operating at the wavelength of 1064 nm, with a pulse duration of 16 ps and a repetition rate of 10 Hz.…”
Section: Methodsmentioning
confidence: 95%
“…The speck extent of the laser beam at the focus was 17.32 mm and the analogous Rayleigh length, which is coupled to the worn laser parameters anticipated was 2.3 mm which persuades the significant state ZR >> L. Consequently, the sample width of 1.3 mm was less than the Rayleigh length and therefore it could be consider as a slim medium. The schematic design of the investigational set-up has already been examined [53,54]. The beam transmission through an opening (aperture) situated in the far-away field was deliberate by photo detector which fed to the digital power meter.…”
Section: Z-scan Methods For Third Order Nonlinearitiesmentioning
confidence: 99%