Comparison of virtual source synthetic aperture beamforming with an element-based model

Abstract: Ultrasound beamforming relies on models of propagation to convert samples of the backscattered field through time into spatial image samples. The most common model is straight-line propagation of a focused wave, assuming a narrow steered and focused beam that propagates along a selected direction. The reconstructed image suffers from defocusing, reduced signal-to-noise ratio (SNR), and contrast loss away from the focus. "Virtual source" methods coherently combine the recorded data from multiple transmissions t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 21 publications
(11 citation statements)
references
References 32 publications
0
11
0
Order By: Relevance
“…Previous work has also demonstrated the similarity of REFoCUS and virtual source reconstructions when imaging with phased arrays. 30…”
Section: Discussionmentioning
confidence: 99%
“…Previous work has also demonstrated the similarity of REFoCUS and virtual source reconstructions when imaging with phased arrays. 30…”
Section: Discussionmentioning
confidence: 99%
“…With n transmissions and T elements, a given time delay τ nT is calculated according to Equation 1.1 for focused waves, Equation 1.2 for plane waves, and Equation 1.3 for diverging waves. (x f ,z f ) gives the position of the virtual source, x n gives the element position, c is the speed of sound, and θ is the steering angle used to direct plane waves [6].…”
Section: Beamforming Methodsmentioning
confidence: 99%
“…Assuming planar wave propagation near the focal point allows for the reconstruction of pixels between the focal points of neighboring beams [25]. The shapes of focused, plane, and diverging wave geometric masks are shown in Figure 1.2 [6]. Note that the planar region near the focal point of the focused transmission is not shown in this configuration.…”
Section: Beamforming Methodsmentioning
confidence: 99%
“…18 For FUI modality, the recent retrospective encoding for conventional ultrasound sequences (REFoCUS) beamforming was introduced, which uses the time shift decoder to remove the transmit delays for each transmitting element to recover the complete data set. 19 Similarly, applying spatially coding in transmission (e.g., Hadamard matrix, S-sequence) and decoding in reception has extended the virtual sources-based beamforming theory for FUI system. 20,21 In addition, shot-profile migration was considered applicable for focused transmit beams, and shows contrast improvement over BiPBF and REFoCUS.…”
Section: Introductionmentioning
confidence: 99%