Comparison of Two Methods of Estimating Reader Variability in QT Interval Measurements in Thorough QT/QTc Studies

Abstract: Background: Two methods of estimating reader variability (RV) in QT measurements between 12 readers were compared.Methods: Using data from 500 electrocardiograms (ECGs) analyzed twice by 12 readers, we bootstrapped 1000 datasets each for both methods. In grouped analysis design (GAD), the same 40 ECGs were read twice by all readers. In pairwise analysis design (PAD), 40 ECGs analyzed by each reader in a clinical trial were reanalyzed by the same reader (intra-RV) and also by another reader (inter-RV); thus, va… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 13 publications
0
4
0
Order By: Relevance
“…7(a) and (b) was 2.75 ± 2.21 ms. This mean was smaller than the average of the differences among readers of cardiologists that was 5.4 ms [24]. In the right side of Fig.…”
Section: Resultsmentioning
confidence: 74%
“…7(a) and (b) was 2.75 ± 2.21 ms. This mean was smaller than the average of the differences among readers of cardiologists that was 5.4 ms [24]. In the right side of Fig.…”
Section: Resultsmentioning
confidence: 74%
“…To obtain a SW-ECG, patients were instructed to hold the stainless steel ring on the top case of the SW continuously for 30 s. Readings from the automated SW-algorithm (HR, PR-, and QT-interval plus QTc) were recorded and a PDF-file of the 30 s single-lead (lead I) SW-ECG was saved. QT-interval on the corresponding 12-lead ECG was manually interpreted by two blinded, independent cardiologists applying the tangent-method ( 8 ), using lead II or V5/V6 as suggested in previous work ( 6 , 8 , 9 ). Bazett’s formula was used to calculate QTc ( 10 ).…”
Section: Methodsmentioning
confidence: 99%
“…A specific assessment of reader variability is also required, with a subset of the ECGs being reread to quantify inter‐ and intrareader variability. Each core lab should have a well‐defined approach to quantifying reader variability …”
Section: Technical Challenges In Conducting a Tqt Studymentioning
confidence: 99%
“…Each core lab should have a well-defined approach to quantifying reader variability. 32 Reviews published in 2005 by Strnadova 33 and 2011 by Satin and colleagues 34 capture respective "snapshots in time" in this field. References to examples of individual TQT studies and related considerations are provided.…”