2021 IEEE 11th International Workshop on Applied Measurements for Power Systems (AMPS) 2021
DOI: 10.1109/amps50177.2021.9586025
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of two different approaches for harmonic distortion sources assessment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 22 publications
0
2
0
Order By: Relevance
“…In Figure 4, R is the line resistance. When a non-linear load is connected to the system, the three-phase currents I A , I B , I C, and neutral current In produce line loss in the line resistance R. The three-phase voltage, current, and phase angle information at measurement Point 2 is collected, and the original three-phase system is equivalently transformed to decompose the load measurement equivalent apparent power S e [24,25]. The equivalent system has the same line power losses as the actual distribution system, and Figure 4 shows a schematic diagram of the three-phase, four-wire low-voltage distribution system after introducing the equivalence.…”
Section: B Three-phase Casementioning
confidence: 99%
See 1 more Smart Citation
“…In Figure 4, R is the line resistance. When a non-linear load is connected to the system, the three-phase currents I A , I B , I C, and neutral current In produce line loss in the line resistance R. The three-phase voltage, current, and phase angle information at measurement Point 2 is collected, and the original three-phase system is equivalently transformed to decompose the load measurement equivalent apparent power S e [24,25]. The equivalent system has the same line power losses as the actual distribution system, and Figure 4 shows a schematic diagram of the three-phase, four-wire low-voltage distribution system after introducing the equivalence.…”
Section: B Three-phase Casementioning
confidence: 99%
“…1459. The IEEE Working Group is in the process of improving the IEEE 1459 standard considering the physical meaning of the measurement theory and reactive power definitions [24,25], but this does not affect the application of the IEEE 1459 standard in line loss calculations and line loss analyses, due to the fact that the line loss itself is caused by the current flowing through the line.…”
Section: Introductionmentioning
confidence: 99%