2020
DOI: 10.1007/s10266-020-00509-9
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of two dental prescale systems used for the measurement of occlusal force

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
40
0
3

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(45 citation statements)
references
References 29 publications
2
40
0
3
Order By: Relevance
“…Japan Fuji Co., Ltd. launched the Dental Prescale system in the early 1990s. The prescale system is a pressuresensitive film (Dental Prescale; Fujifilm Co., Tokyo, Japan) with analysis equipment (Occluzer FPD703; GC Corp., Tokyo, Japan) (Shiga et al, 2020). The pressure-sensitive film is a pressuresensitive horseshoe-shaped sheet comprised of two polyethylene terephthalate films and many microcapsules containing colorforming materials placed between them.…”
Section: Pressure Sensitive Filmmentioning
confidence: 99%
See 1 more Smart Citation
“…Japan Fuji Co., Ltd. launched the Dental Prescale system in the early 1990s. The prescale system is a pressuresensitive film (Dental Prescale; Fujifilm Co., Tokyo, Japan) with analysis equipment (Occluzer FPD703; GC Corp., Tokyo, Japan) (Shiga et al, 2020). The pressure-sensitive film is a pressuresensitive horseshoe-shaped sheet comprised of two polyethylene terephthalate films and many microcapsules containing colorforming materials placed between them.…”
Section: Pressure Sensitive Filmmentioning
confidence: 99%
“…After recording, the film is stored in a light-resistant container and transported at room temperature for analysis. To maintain the reliability of the measurement, the data must be analyzed on the same day using the analysis equipment Occluzer FPD705 (FujiFilm GC) (Shiga et al, 2020). By scanning the colored image after compression, the number, position, force size and force distribution of the occlusal contact points are obtained.…”
Section: Pressure Sensitive Filmmentioning
confidence: 99%
“…e Eichner index (EI) was used as an evaluation of occlusal condition based on existing natural tooth contacts between the maxilla and mandible in the bilateral premolar and molar regions. BF was recorded using the Bite Force Analyzing System (GC, Tokyo, Japan) [8]. is method uses a sheet that undergoes a color-developing chemical reaction when bitten.…”
Section: Clinicalmentioning
confidence: 99%
“…e number of bacteria was quantified (in cfu/mL) using the dielectrophoretic impedance measurement technique. e number of oral bacteria was classified into seven levels as follows: Level 1, <10 5 ; Level 2, 10 5 -10 6 ; Level 3, 10 6 -10 6.5 ; Level 4, 10 6.5 -10 7 ; Level 5, 10 7 -10 7.5 ; Level 6, 10 7.5 -10 8 ; and Level 7, >10 8 . e participants were divided into two groups: those > Level 5, indicative of the need for professional oral care, and those ≤ Level 5 [9].…”
Section: Clinicalmentioning
confidence: 99%
“…To measure the MOF, a pressure-sensitive lm (Dental Prescale II, GC, Tokyo, Japan) was aligned with the dentition, and the participant was instructed to bite with maximum force. The scanner was calibrated [15], the pressuresensitive lm was tted to the template, and analysis was performed with analysis software (Bite Force Analyzer GC, Tokyo, Japan).…”
Section: Measurement Of Mof Ma Mmt and Mmeimentioning
confidence: 99%