2018
DOI: 10.1101/429977
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Comparison of tri-exponential decay vs. bi-exponential decay and full fitting vs. segmented fitting for modeling liver intravoxel incoherent motion diffusion MRI

Abstract: Purpose:To determine whether bi-or tri-exponential models, and full or segmented fittings, better fit IVIM imaging signal of healthy livers. Materials and methods:Diffusion-weighted images were acquired with a 3-T scanner using respiratory-triggered echo-planar sequence and 16 b-values (0~800 s/mm 2 ). Eighteen healthy volunteers had liver scanned twice in the same session, and then once again in another session.Region of interest (ROI)-based measurements were processed with bi-exponential model full fitting a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
10
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(12 citation statements)
references
References 28 publications
2
10
0
Order By: Relevance
“…Our this study, using a new set of healthy volunteers (n=26) and patients' data (n=16), provides a confirmation of our previous report (15). The value of IVIM parameters depend on the number and distribution of b-value series, as well as the threshold b-value when segmented fitting is applied (31)(32)(33). Moreover, it has been noted that the dependence of PF, Dslow, and Dfast on threshold b-value differs between healthy livers and fibrotic livers, with the healthy livers showing a higher degree of dependence (23).…”
Section: Discussionsupporting
confidence: 81%
See 4 more Smart Citations
“…Our this study, using a new set of healthy volunteers (n=26) and patients' data (n=16), provides a confirmation of our previous report (15). The value of IVIM parameters depend on the number and distribution of b-value series, as well as the threshold b-value when segmented fitting is applied (31)(32)(33). Moreover, it has been noted that the dependence of PF, Dslow, and Dfast on threshold b-value differs between healthy livers and fibrotic livers, with the healthy livers showing a higher degree of dependence (23).…”
Section: Discussionsupporting
confidence: 81%
“…The same as our last study (15), among the three IVIM parameters, PF also showed best diagnostic performance in this study. According to previous estimation, Dfast should be the most sensitive parameter for liver fibrosis evaluation (14,15,23); however, precise measurement of Dfast is difficult and this current study did not include sufficient very low b-values for precise Dfast quantification (33,34). More b-values and applying an optimized b-value distribution shall be able to reduce errors in IVIM parameter estimation.…”
Section: Discussionmentioning
confidence: 91%
See 3 more Smart Citations