1995
DOI: 10.1016/s0022-3913(05)80373-7
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of the torsional forces at failure for seven endodontic post systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
0
1

Year Published

1998
1998
2012
2012

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(12 citation statements)
references
References 21 publications
1
10
0
1
Order By: Relevance
“…The retention of silver amalgam was slightly less than that of composite, while that of the glass–ionomer was significantly lower than that of the other two materials. Other researchers reported similar results ( Volwiler et al ., 1989 ; Chang & Millstein, 1993; Cohen et al , 1995 ). It has been reported that silver amalgam retain slightly more strongly to the post head than composite ( Chang & Millstein, 1993).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The retention of silver amalgam was slightly less than that of composite, while that of the glass–ionomer was significantly lower than that of the other two materials. Other researchers reported similar results ( Volwiler et al ., 1989 ; Chang & Millstein, 1993; Cohen et al , 1995 ). It has been reported that silver amalgam retain slightly more strongly to the post head than composite ( Chang & Millstein, 1993).…”
Section: Discussionmentioning
confidence: 99%
“…While custom‐cast tapered posts and cores are traditionally used to restore endontically treated teeth, prefabricated posts have become very popular ( Torbjorner, Karlsson & Odman, 1995). Over the years, various prefabricated post systems have been introduced and successfully used in clinical settings ( Greenfeld et al ., 1989 ; Cohen et al ., 1995 ).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Single implant-supported restorations can also be subject to rotational or torsion forces, whenever they are clinically demanded through the functional contacts cusp/marginal ridge, that is, in a one tooth to two teeth relation (Cohen et al, 1995). Figure 27 shows tensile stresses between 50 and 300 MPa on the abutment, which was already expected, in view of the direction of the force on the crown, which pulls the implant in this area.…”
Section: Torsion Effect -Load Of 45˚ On the Mesial Marginal Ridgementioning
confidence: 90%
“…A post is commonly placed in an attempt to strengthen the tooth (1,2). However, in vitro and in vivo studies have demonstrated that a dowel does not reinforce endodontically treated teeth, in spite of improving retention when little amount of clinical crown is remaining (3)(4).…”
Section: Introductionmentioning
confidence: 99%