2019
DOI: 10.1016/j.bja.2018.11.011
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of the TOF-Cuff® monitor with electromyography and acceleromyography during recovery from neuromuscular block

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
13
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(14 citation statements)
references
References 10 publications
1
13
0
Order By: Relevance
“…Our study sample size was similar to other reported investigations [7,14], but still relatively small and homogenous, which limits our ability to generalize our results. Using the gold standard in neuromuscular monitoring, mechano-or electromyography, as our control device could have strengthened the robustness of our investigation.…”
Section: Discussionsupporting
confidence: 71%
See 1 more Smart Citation
“…Our study sample size was similar to other reported investigations [7,14], but still relatively small and homogenous, which limits our ability to generalize our results. Using the gold standard in neuromuscular monitoring, mechano-or electromyography, as our control device could have strengthened the robustness of our investigation.…”
Section: Discussionsupporting
confidence: 71%
“…A newly developed neuromuscular monitor, the TOF-Cuff® (RGB medical devices; Madrid, Spain), incorporates both stimulating electrodes and sensors into a blood pressure cuff [5][6][7]. In addition to the ease of application and use, this dual-purpose device does not require specific limb positioning or expensive components used with other monitoring systems.…”
Section: Introductionmentioning
confidence: 99%
“…Their common feature is their user-friendly interface, but validation studies are needed to compare their performance and usability to existing monitors and to prove their consistency and reliability in the clinical setting. [10][11][12][13][14][15][16] Until recently, the most frequently used neuromuscular monitors were acceleromyography-based devices. To obtain precise train-of-four ratio measurements with these devices, clinicians need to take several precautions (such as fixation of the arm in supine position, use of preload on the thumb, calibration of the device, and normalization of results).…”
Section: What We Already Know About This Topicmentioning
confidence: 99%
“…TOF-cuff has the advantage of convenience because it uses a modified blood pressure cuff on the arm for neuromuscular monitoring, but has limitations of underestimation in the measurement of TOF ratios and inaccuracy for the prevention of RNMB in comparison to the EMG or AMG [27]. Recent studies showed delayed recovery to a normalized TOF ratio of >0.9, approximately 25-minute longer, with EMG or AMG compared with TOF-Cuff [28].…”
Section: Modern Technical Development Of Neuromuscular Monitoring Devicesmentioning
confidence: 99%