1994
DOI: 10.1016/0278-2391(94)90294-1
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of the resistance of miniplates and microplates to various in vitro forces

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0
3

Year Published

2014
2014
2019
2019

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 19 publications
0
4
0
3
Order By: Relevance
“…In 2005, Choi et al 25 used beef ribs to simulate fractures in edentulous mandibles and to analyze the mechanical behavior of the system using different strategies, but according to the findings by Hegtvedt et al, 26 the mechanical behavior of materials shows differences when they are evaluated separately than when fractures are simulated using animal bones.…”
Section: Choi Y Colaboradoresmentioning
confidence: 99%
“…In 2005, Choi et al 25 used beef ribs to simulate fractures in edentulous mandibles and to analyze the mechanical behavior of the system using different strategies, but according to the findings by Hegtvedt et al, 26 the mechanical behavior of materials shows differences when they are evaluated separately than when fractures are simulated using animal bones.…”
Section: Choi Y Colaboradoresmentioning
confidence: 99%
“…2 Surgical treatment has been the choice in many cases, with good results. 3,4 One of the options for osteosynthesis in the area of tension and compression 5 has been employed with great success and has demonstrated great versatility when different types of systems are used with monocortical or bicortical screws, depending on the area of approach. Different technologies, including resorbable internal fixation systems, have been used in different cases of maxillofacial surgery with good results.…”
mentioning
confidence: 99%
“…O padrão de falha se deu igual nos dois grupos estudados. KAMEYAMA, 1995;KOHN et al, 1995;SCHWIMMER et al, 1994;THROCKMORTON et al, 1992) ERKMEN et al, 2005aERKMEN et al, , 2005bFOLEY, 1994;FOLEY et al, 1989;HAUG, 1996;KIM et al, 1993;KOHN et al, 1995;HOLWEG;SCHUBERT, 1999;MURPHY;BARBER, 1997;OZDEN et al, 2006;SHETTY, 1997;SHETTY et al, 1996aSHETTY et al, , 1996bTHARANON, 1998; CROFTS et al, 1990;FOLEY;BECKMAN, 1992;GOMES;GUIMARÃES FILHO;MAZZONETTO, 2003;HAUG, 1993;PUNJABI, 1999;HEGTVEDT;MICHAELS;BEALS, 1994;IKEMURA et al, 1984IKEMURA et al, , 1988LEE;PIECUCH, 1992;LOUKOTA;SHELTON, 1995;MURPHY;BARBER, 1997 ARMSTRONG et al, 2001). Entretanto, num modelo experimental essa falência do sistema de fixação pode ser definida como um ponto de inflexão entre a fase elástica e plástica na curva de carga versus deslocamento (EDWARDS; DAVID, 1996;…”
Section: Resultsunclassified