2023
DOI: 10.7759/cureus.37223
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of the Rate of Posterior Capsule Opacification Following Combined Treatment With Topical Dexamethasone 0.1% Plus Ketorolac 0.5% Eye Drops Versus Dexamethasone 0.1% Alone: A Two-Year, Randomized Clinical Investigation

Abstract: Background and aimThe use of non-steroidal anti-inflammatory drugs in animals decreases the incidence of posterior capsular opacification (PCO) following cataract surgery. We evaluated the rate of PCO in patients with cataract surgery and foldable "in the bag" posterior chamber intraocular lens (PC-IOL) implantation treated with combined dexamethasone 0.1% plus ketorolac tromethamine 0.5% versus dexamethasone 0.1% alone. Materials and methodsA total of 114 eyes of 101 patients underwent uneventful corneal smal… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
0
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 25 publications
0
0
0
Order By: Relevance
“…The nucleus was emulsified in the posterior chamber and the remaining lenticular material was aspirated by the phaco probe. After the meticulous cortical cleanup was performed, the anterior chamber and the capsular bag were filled with viscoelastic material again, and a foldable acrylic IOL was implanted in the bag and inserted through the main superior surgical opening [11]. After the folding process of the soft IOL within the cartridges was completed, the insertion of the soft acrylic posterior chamber IOLs was performed via the manual Monarch delivery system (Alcon, Fort Worth, TX, USA).…”
Section: Methodsmentioning
confidence: 99%
“…The nucleus was emulsified in the posterior chamber and the remaining lenticular material was aspirated by the phaco probe. After the meticulous cortical cleanup was performed, the anterior chamber and the capsular bag were filled with viscoelastic material again, and a foldable acrylic IOL was implanted in the bag and inserted through the main superior surgical opening [11]. After the folding process of the soft IOL within the cartridges was completed, the insertion of the soft acrylic posterior chamber IOLs was performed via the manual Monarch delivery system (Alcon, Fort Worth, TX, USA).…”
Section: Methodsmentioning
confidence: 99%