2014 IEEE Energy Conversion Congress and Exposition (ECCE) 2014
DOI: 10.1109/ecce.2014.6953736
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of the Perturb and Observe and simulated annealing approaches for maximum power point tracking in a photovoltaic system under partial shading conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(6 citation statements)
references
References 40 publications
0
6
0
Order By: Relevance
“…This feature is obvious, especially in multi-input microinverters, because PV modules are connected in each phase. For a single PV module, simple and well-known MPPT techniques, such as perturb-and-observe and incremental-conductance algorithms, are used for normal and under partial shading conditions (see [50,51]). For multiples PV modules, advanced techniques such as particle swarm and overall MPPT should be employed to guarantee maximum power transfer from the PV modules to the grid [52,53].…”
Section: Dmpptmentioning
confidence: 99%
See 2 more Smart Citations
“…This feature is obvious, especially in multi-input microinverters, because PV modules are connected in each phase. For a single PV module, simple and well-known MPPT techniques, such as perturb-and-observe and incremental-conductance algorithms, are used for normal and under partial shading conditions (see [50,51]). For multiples PV modules, advanced techniques such as particle swarm and overall MPPT should be employed to guarantee maximum power transfer from the PV modules to the grid [52,53].…”
Section: Dmpptmentioning
confidence: 99%
“…Finally, a three-phase four-leg inverter was employed to ensure the reliable operation of the PV architecture under balanced and unbalanced load conditions. o CMV: CMV in Z-source microinverter topologies can be mitigated using modified switching states [50]. Moreover, CMV is highly reduced in isolated Z-source [103] topologies.…”
Section: Three-phase Z Source Invertermentioning
confidence: 99%
See 1 more Smart Citation
“…While traditionally used for global minimisation, a small change to the key criteria of the method enables it to be used for global maximisation. The SA-based MPPT method has been applied to uniform [101] and non-uniform operating conditions [102,103] and exhibits good performance under both with limited optimisation of the parameters. To find the MPP with the SA-based method, an initial temperature, final temperature and cooling rate must be defined.…”
Section: Simulated Annealingmentioning
confidence: 99%
“…Partial shading will greatly reduce the PV module production, and lead to multiple local maximum power points, as shown in Figure 1. The latter effect makes the conventional MPPT algorithms (such as P&O or INC) difficult to track the global MPP [11][12][13].…”
Section: Introductionmentioning
confidence: 99%