Comparison of the Nidek EAS 1000 System and the Topcon SL-45 in Clinical Application

Abstract: Some years ago, Nidek developed a new imaging system for the anterior eye segment, which offers the possibility of recording Scheimpflug and retroillumination images. The system consists of 2 different technical units, a camera unit for image recording and a computer unit for storage, system operation and image analysis. To evaluate the clinical use of the system and its reproducibility, a study with 31 volunteers/patients was performed that were photographed with the Nidek EAS 1000 at the meridians 0°, 45° an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0
2

Year Published

1994
1994
2011
2011

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(15 citation statements)
references
References 11 publications
0
13
0
2
Order By: Relevance
“…Implementing Scheimpflug and retroillumination digital photography with computerised analysis of lens opacities has allowed progression of cataract to be measured with great precision. [71][72][73][74][75][76][77][78][79][80][81][82][83][84][85][86][87][88] This method, cost effective for the large epidemiological studies, 89 is probably the best technique for recording cataract changes.…”
Section: Quantification Of Lens Opacity Measurements In Risk Factor Amentioning
confidence: 99%
“…Implementing Scheimpflug and retroillumination digital photography with computerised analysis of lens opacities has allowed progression of cataract to be measured with great precision. [71][72][73][74][75][76][77][78][79][80][81][82][83][84][85][86][87][88] This method, cost effective for the large epidemiological studies, 89 is probably the best technique for recording cataract changes.…”
Section: Quantification Of Lens Opacity Measurements In Risk Factor Amentioning
confidence: 99%
“…It has been used in the assessment of cataract [6][7][8] and for measuring corneal curvature and thickness. 9 It is a rotating camera that offers a noninvasive assessment of the anterior segment of the eye.…”
mentioning
confidence: 99%
“…We used the Scheimpflug system EAS-1000 of Nidek Co. with digital image analysis. The same system allows to take additional retroillumination photographs and their analysis [8][9][10]. We could prove in a former exploration the good quality and reliability of biometric data in pseudophacic eyes obtained by this system [11,12].…”
Section: Methodsmentioning
confidence: 99%