Comparison of the influence of cataract and pupil size on retinal nerve fibre layer thickness measurements with time-domain and spectral-domain optical coherence tomography

Abstract: Cataracts, not pupil size, cause significant underestimation of RNFL measurements in both Cirrus and Stratus OCT. The extent of influence exerted does not appear different between the two instruments. Reproducibility of each machine appears to be affected differently. Mydriasis is required to achieve excellent reproducibility with Cirrus OCT, and media clarity is required with Stratus OCT.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

5
22
0
5

Year Published

2012
2012
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 42 publications
(32 citation statements)
references
References 24 publications
5
22
0
5
Order By: Relevance
“…27,28 In addition, one should bear in mind that, in the current study, all scans were acquired under mydriasis, and RNFL measurements before and after mydriasis might not be interchangeable for some Fd-OCT devices. 30,31 Whereas other commercially available Fd-OCT instruments provide an axial resolution and scanning speed comparable to the one used in the current study and may also include a ''testretest'' software function, the Spectralis was the first Fd-OCT to integrate active real-time eye tracking (EBF function). This dual-beam eye-tracking technology mitigates eye motion artifacts and ensures point-to-point correlations between OCT and fundus images without postprocessing of the data.…”
Section: Discussionmentioning
confidence: 99%
“…27,28 In addition, one should bear in mind that, in the current study, all scans were acquired under mydriasis, and RNFL measurements before and after mydriasis might not be interchangeable for some Fd-OCT devices. 30,31 Whereas other commercially available Fd-OCT instruments provide an axial resolution and scanning speed comparable to the one used in the current study and may also include a ''testretest'' software function, the Spectralis was the first Fd-OCT to integrate active real-time eye tracking (EBF function). This dual-beam eye-tracking technology mitigates eye motion artifacts and ensures point-to-point correlations between OCT and fundus images without postprocessing of the data.…”
Section: Discussionmentioning
confidence: 99%
“…yapmış olduğu bir çalışmada katarakt ameliyatı sonrası ortalama peripapiller RSLT kalınlığında; hem Cirrus OKT hem de Stratus OKT ile istatistiksel olarak anlamlı bir artış saptamışlardır. 40 Bu artış hem ortalama peripapiller 360 derecede hem de dört kadranda olmuştur. Bu çalış-mada, global lens opasite derecesi ile ameliyat sonrası, ortalama RSLT kalınlığı artışı arasında, iki cihaz ile de korelasyon saptanmamıştır.…”
unclassified
“…37 Bu çalışmada ayrıca RSLT kalınlığı ölçümünü kataraktın, pupil çapından belirgin olarak daha fazla etkilediği saptanmıştır. 40 Bizim ça-lışmamızda ise tüm hastalar dilate edildikten sonra ölçümler yapıldığı için, pupil çapı etkisi değerlen-dirme dışı bırakılmıştır.…”
unclassified
See 2 more Smart Citations