2022
DOI: 10.3928/1081597x-20220725-01
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of the Functional Optical Zone in Eyes With High Myopia With High Astigmatism After SMILE and FS-LASIK

Abstract: PURPOSE: To compare the functional optical zone (FOZ) in eyes with high myopia with high astigmatism after small incision lenticule extraction (SMILE) and femtosecond laser–assisted laser in situ keratomileusis (FS-LASIK). METHODS: In total, 45 eyes of 45 patients with high myopia with astigmatism greater than 2.00 diopters (D) who underwent SMILE or FS-LASIK were enrolled. The FOZ, optical zone decentration, and corneal aberrations were analyzed using … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…Previously, the method commonly used to analyze the EOZ diameter was the average gured by manual multi-radial measurement [9,12]. This method may be limited by low measurement e ciency and poor repeatability.…”
Section: Discussionmentioning
confidence: 99%
“…Previously, the method commonly used to analyze the EOZ diameter was the average gured by manual multi-radial measurement [9,12]. This method may be limited by low measurement e ciency and poor repeatability.…”
Section: Discussionmentioning
confidence: 99%
“…Twelve points where a 0 D difference was detected between the pre-and post-scans were measured at every consecutive 30 degrees moving counterclockwise from 0° in order to approximate the EOZ. 11,12,14 Python 3.11 (Python Software Foundation) was used to run the publicly available NumPy best fitting ellipse program, which provides data such as the ellipse's center point, area, axis lengths, and eccentricity. In this study, the major and minor axes are called major and minor diameters, and they denote the transected distance in mm between the two elliptical points that are farthest from, and closest to, each other, respectively.…”
Section: Surgical Techniquementioning
confidence: 99%
“…Wu et al also found SMILE superior to FS-LAIK in uncorrected distance visual acuity and optical quality at postoperative year 1 [25]. SMILE may also have added benefits over FS-LASIK in the high myopia group such as a smaller decrease in functional optical zone (FOZ) [26], a key marker of visual quality [27] and less increase in overall higher order aberration specifically spherical aberration [25,28]. Lastly, SMILE theoretically preserves more corneal stress resistance [29].…”
Section: Introductionmentioning
confidence: 97%