2015
DOI: 10.1016/j.ophtha.2015.05.013
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Sulfur Hexafluoride 20% versus Air Tamponade in Descemet Membrane Endothelial Keratoplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

8
71
3
3

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 95 publications
(90 citation statements)
references
References 39 publications
8
71
3
3
Order By: Relevance
“…11 Eventually, this promising approach could reduce the amount of gas filling needed to provide adequate support for the graft during the crucial period after surgery. A recent study by Güell et al 15 has found that using 20% SF 6 gas leads to a lower rebubbling rate after DMEK (12.8% with air vs. 2.4% with SF 6 gas) with a bubble size comparable to that of the larger bubble group in this study. Terry et al 14 have also recently investigated the usage of 20% SF 6 gas.…”
Section: Discussionsupporting
confidence: 66%
“…11 Eventually, this promising approach could reduce the amount of gas filling needed to provide adequate support for the graft during the crucial period after surgery. A recent study by Güell et al 15 has found that using 20% SF 6 gas leads to a lower rebubbling rate after DMEK (12.8% with air vs. 2.4% with SF 6 gas) with a bubble size comparable to that of the larger bubble group in this study. Terry et al 14 have also recently investigated the usage of 20% SF 6 gas.…”
Section: Discussionsupporting
confidence: 66%
“…A recent study of 44 patients who underwent DSEK compared SF 6 with air for graft attachment and noted that, although patients who received air had five graft detachments, there were no detachments reported in the group that received SF 6 (8) . Additionally, Guell et al, recently demonstrated reduced detachment rates with SF 6 from those with air in their series, and no effect on corneal endothelial cell counts was observed (9) . In the present study, we compared graft detachment rates between SF 6 and air for intraocular tamponade in DMEK.…”
Section: Resultados: a Taxa De Descolamento Do Botão Endotelial Foi Dmentioning
confidence: 79%
“…A recent in vitro study, however, found no significant difference between SF 6 and air on endothelial cell counts or toxicity of corneal endothelial cells (14) . Additionally, Guell et al found no difference in endothelial cell counts between use of SF 6 or air ≤3years after DMEK (9) . One weakness of our study was that the SF 6 procedures followed the air procedures chronologically because detachment rates have been found to diminish with experience of the surgeon (15) .…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…10,11,15,25 With an improved surgical technique, the number is reported as low as 12%. 26 The lack of standardized criteria for rebubbling in DMEK makes it difficult to systematically compare the rate of rebubbling between various techniques from different …”
Section: Discussionmentioning
confidence: 99%