Comparison of Speed of Sound Measures Assessed by Multisite Quantitative Ultrasound to Bone Mineral Density Measures Assessed by Dual-Energy X-Ray Absorptiometry in a Large Canadian Cohort: the Canadian Multicentre Osteoporosis Study (CaMos)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 27 publications
0
9
0
Order By: Relevance
“…The system is equipped with a convex 3.5 MHz transducer, which simultaneously detects B-mode ultrasound signals and unprocessed radiofrequency signals. Those which are analyzed by the machine's statistical algorithm (EchoStudio ® ; Echolight SRL) for each region of interest (ROI), taking into account the patient's ethnicity, age, sex and BMI and comparing them to a database of ~10,000 subjects (18,20,2426). The ROI for each patient included the usual sites for the diagnosis of osteoporosis: The lumbar spine (L1-L4 vertebrae approached from the abdomen) and the femoral necks.…”
Section: Methodsmentioning
confidence: 99%
“…The system is equipped with a convex 3.5 MHz transducer, which simultaneously detects B-mode ultrasound signals and unprocessed radiofrequency signals. Those which are analyzed by the machine's statistical algorithm (EchoStudio ® ; Echolight SRL) for each region of interest (ROI), taking into account the patient's ethnicity, age, sex and BMI and comparing them to a database of ~10,000 subjects (18,20,2426). The ROI for each patient included the usual sites for the diagnosis of osteoporosis: The lumbar spine (L1-L4 vertebrae approached from the abdomen) and the femoral necks.…”
Section: Methodsmentioning
confidence: 99%
“…However, the relative contributions of structural and material properties to the measured sound propagation characteristics remain challenging to discern [46]. QUS devices are portable, use non-ionizing radiation, and are increasingly applied in clinical studies [48,49] at distal sites of the skeleton (e.g., radius and tibia), which represent the same imaging target of HR-pQCT. With this respect, 3D descriptions of the local cortical porosity obtained from HR-pQCT could be combined with site-matched experimental measurements and numerical simulations of ultrasound propagation in long bones, to help elucidating the interplay between ultrasound and the cortical microstructure.…”
Section: A Bmd-based Measurement Of Ct Po Localmentioning
confidence: 99%
“…Studies investigating the association between the measurements of DXA and QUS revealed inconsistent results. While a number of studies showed a significant positive correlation between DXA and QUS ( Van Rijn et al, 2000 ; Di Mase et al, 2012 ; Falcini et al, 2000 ; Gonçalves et al, 2014 ; Hartman et al, 2004a ; Pluskiewicz et al, 2002 ; Sani et al, 2011 ; Sundberg et al, 1998 ; Xu et al, 2014 ; Bąk-Drabik et al, 2016 ; Catalano et al, 2017 ; Olszynski et al, 2016 ; Zuckerman-Levin et al, 2007 ; Mora et al, 2009 ; Weeks et al, 2016 ; Halaba et al, 2005 ; Catalano et al, 2013 ), others found a discrepancy between the measurements of the two methods ( Gianni et al, 2008 ; Halaba et al, 2005 ; Chong et al, 2015 ; Christoforidis et al, 2010 ; Christoforidis et al, 2011 ; Hartman et al, 2004b ; Williams et al, 2012 ; Alwis et al, 2010 ). This could be a result of the different QUS measurement sites or different patient categories investigated.…”
Section: Introductionmentioning
confidence: 99%
“…This could be a result of the different QUS measurement sites or different patient categories investigated. Only a limited number of studies used the phalangeal QUS ( Di Mase et al, 2012 ; Gonçalves et al, 2014 ; Pluskiewicz et al, 2002 ; Bąk-Drabik et al, 2016 ; Catalano et al, 2017 ; Olszynski et al, 2016 ; Halaba et al, 2005 ; Catalano et al, 2013 ) and only one study looked at the specific group of former preterm born children ( Gianni et al, 2008 ).…”
Section: Introductionmentioning
confidence: 99%