Comparison of Speciation Sampler and PC-BOSS Fine Particulate Matter Organic Material Results Obtained in Lindon, Utah, during Winter 2001–2002

Abstract: The Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) has been previously verified as being capable of measuring total fine particulate matter (PM 2.5 ), including semi-volatile species. The present study was conducted to determine if the simple modification of a commercial speciation sampler with a charcoal denuder followed by a filter pack containing a quartz filter and a charcoal-impregnated glass (CIG) fiber filter would allow for the measurement of total PM 2.5 , including s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(11 citation statements)
references
References 21 publications
0
11
0
Order By: Relevance
“…On the basis of data obtained in several studies with a charcoal-impregnated filter using a parallel plate denuder 4,5,8,9,14,18,20 the initial peak in the data is due to the small fraction of the gas-phase organic material entering the denuder that is not removed by the denuder, and this material is well separated from SVOC lost from particles. For the sample given in Figure 1B, this initial peak is about half the size of the larger peakin the 220 -450°C temperature step.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…On the basis of data obtained in several studies with a charcoal-impregnated filter using a parallel plate denuder 4,5,8,9,14,18,20 the initial peak in the data is due to the small fraction of the gas-phase organic material entering the denuder that is not removed by the denuder, and this material is well separated from SVOC lost from particles. For the sample given in Figure 1B, this initial peak is about half the size of the larger peakin the 220 -450°C temperature step.…”
Section: Resultsmentioning
confidence: 99%
“…Denuder strips were not changed during the Rubidoux study because the study duration of 4 weeks was not expected to result in a significant degradation of denuder efficiency on the basis of previous studies. 14 …”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations