2020
DOI: 10.1088/1748-0221/15/09/c09066
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of single crystal diamond TOF detectors in planar and transverse configuration

Abstract: Single crystal diamond detectors are widely employed in laser-induced plasma experiments to retrieve information about particles generated from the interaction. In particular, diamonds are used as Time of Flight (TOF) detectors featured by good sensitivity, high radiation hardness and fast response time. In this work, we provide a detailed characterization of two different types of electrodes configuration retrieving their charge collection efficiency, temporal response, and effective active area. The so obtai… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

4
1

Authors

Journals

citations
Cited by 9 publications
(22 citation statements)
references
References 28 publications
(34 reference statements)
0
20
0
Order By: Relevance
“…The Charge Collection Efficiency was estimated by exposing the detector to the 241 Am sample for 300 s. Thus, several events were detected by the diamond detector during the acquisition time. The output signals were processed by a conventional charge-sensitive electronic chain [12,13,20]. They were first integrated by a charge-sensitive preamplifier (ORTEC 142A).…”
Section: Time Response and Charge Collection Efficiency Measurementsmentioning
confidence: 99%
See 2 more Smart Citations
“…The Charge Collection Efficiency was estimated by exposing the detector to the 241 Am sample for 300 s. Thus, several events were detected by the diamond detector during the acquisition time. The output signals were processed by a conventional charge-sensitive electronic chain [12,13,20]. They were first integrated by a charge-sensitive preamplifier (ORTEC 142A).…”
Section: Time Response and Charge Collection Efficiency Measurementsmentioning
confidence: 99%
“…These charges are then collected at the electrodes generating the signal. Knowing the detector response and the ion type, it is possible to retrieve the number of particles impinging onto the detector for each energy range [8,13].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The time-of-flight measurements were carried out by means of a single crystal chemical vapor deposition diamond detector having a thickness of 50 𝜇𝑚 and interdigited electrodes [40]. Given the expected high level of produced EMPs, the set-up of the diagnostic and the acquisition system was done following the procedure described in Refs.…”
Section: Tof Proton Spectrum Measurements Using a Diamond Detectormentioning
confidence: 99%
“…The particle spectrum can be calculated from TOF data, but only supposing the particle species on the basis of physical considerations [4][5][6]. Similarly, magnetic spectrometers relate the particle properties with the deflection, but they are useful only when the particle species is known, for example with electron beams.…”
Section: Introductionmentioning
confidence: 99%