2022
DOI: 10.1097/bpo.0000000000002212
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Shoulder Motion Measurements by Visual Estimate, Goniometer and Motion Capture

Abstract: Background: Brachial plexus birth injuries (BPBI) can result in lasting impairments of external rotation and cross-body adduction (CBA) that disrupt functional activities such as dressing, grooming, or throwing a ball. The purpose of this study was to compare the quantification of shoulder humerothoracic (HT) external rotation (ER), and glenohumeral (GH) CBA by 3 methodsphysician visual estimate, goniometer measurement by an occupational therapist, and motion capture. Methods: Twenty-six patients with BPBI (av… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(9 citation statements)
references
References 43 publications
0
9
0
Order By: Relevance
“…Furthermore, MediaPipe’s average error of 8.57 is below the error of tools commonly used in physical therapy clinics for joint angle assessment. Additionally, compared to the results obtained by Russo [ 15 ], the human error for angular measurements is 12.78 degrees. Thus, MediaPipe scored excellent for all data and lower limbs and good metric for upper limbs.…”
Section: Discussionmentioning
confidence: 81%
See 2 more Smart Citations
“…Furthermore, MediaPipe’s average error of 8.57 is below the error of tools commonly used in physical therapy clinics for joint angle assessment. Additionally, compared to the results obtained by Russo [ 15 ], the human error for angular measurements is 12.78 degrees. Thus, MediaPipe scored excellent for all data and lower limbs and good metric for upper limbs.…”
Section: Discussionmentioning
confidence: 81%
“…In Table 4 , it is possible to see the error for all movements and split for upper and lower limbs movements. In addition, it is possible to analyze its classification in relation to human error performed in clinical practice (12.78 ± 7.44 degrees) [ 15 ].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…reachable workspace) and can differentiate glenohumeral and scapulothoracic joint motion. 4 5 Motion analysis yields a more accurate and nuanced assessment of shoulder function than can be obtained from a Mallet score. 5…”
Section: Assessmentmentioning
confidence: 99%
“…4 5 Motion analysis yields a more accurate and nuanced assessment of shoulder function than can be obtained from a Mallet score. 5…”
Section: Assessmentmentioning
confidence: 99%