Abstract: SummaryNinety-one patients were randomly allocated to one of two groups. Group A was induced with a single vital capacity breath of 6% (end-tidal) sevoflurane in nitrous oxide±oxygen (2 : 1 l.min 21 ), whereas group B was induced with intravenous fentanyl 1 mg.kg 21 1 propofol 2 mg.kg 21 followed by nitrous oxide±oxygen (2 : 1 l.min 21 ) and sevoflurane. Induction was considered to have been achieved when the bispectral index value decreased to below 70. Mean induction time in group A (95.2 s, 95% CI 88.5±101.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2004
2004
2014
2014

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 14 publications
(25 reference statements)
0
2
0
Order By: Relevance
“…Impedance was kept below 5 k. Electroencephalography spectral analysis was performed in periods of artefactfree EEG (see below) with Fast Fourier Transform algorithm calculation power values of delta (0.1-4.0 Hz), theta (4-8 Hz), alpha (8)(9)(10)(11)(12), and beta bands (12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25)(26)(27)(28)(29)(30). Sixteen tin-cup electrodes (Medtronis Functional diagnostics A/S, Skovlunde, Denmark) were placed across the scalp according to the 10-20 International System supplemented by the two linked-ears reference.…”
Section: Electroencephalographymentioning
confidence: 99%
See 1 more Smart Citation
“…Impedance was kept below 5 k. Electroencephalography spectral analysis was performed in periods of artefactfree EEG (see below) with Fast Fourier Transform algorithm calculation power values of delta (0.1-4.0 Hz), theta (4-8 Hz), alpha (8)(9)(10)(11)(12), and beta bands (12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25)(26)(27)(28)(29)(30). Sixteen tin-cup electrodes (Medtronis Functional diagnostics A/S, Skovlunde, Denmark) were placed across the scalp according to the 10-20 International System supplemented by the two linked-ears reference.…”
Section: Electroencephalographymentioning
confidence: 99%
“…On the screen it displays an active (moving) analogue waveform and a numerical value, the BIS value, which is updated every 2 s. The BIS value, a measure of the hypnotic effects of anaesthetics, ranges from 0 to 100 (95-100 when the patient is awake, 80 with light hypnotic effects, 70 with moderate hypnotic effects, 60 indicating unconsciousness and 40 with deep hypnotic effects) (18). This module acquires and processes realtime EEG data into one channel.…”
Section: Bispectral Index Monitoringmentioning
confidence: 99%