Comparison of sandblasting, laser irradiation, and conventional acid etching for orthodontic bonding of molar tubes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

4
45
0
21

Year Published

2009
2009
2018
2018

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 65 publications
(73 citation statements)
references
References 20 publications
4
45
0
21
Order By: Relevance
“…9 Where bond strengths (MPa) and base surface areas are quoted, it was possible to retrospectively calculate forces to failure. This enabled mean force to failure values to be determined from data from two previous bond strength studies as 158.08 N, 17 which is higher than the mean force to failure values achieved in the current study (90.34 N to 130.17 N), and 128.47 N, 18 which is comparable with findings of the current study.…”
Section: Discussionsupporting
confidence: 81%
See 2 more Smart Citations
“…9 Where bond strengths (MPa) and base surface areas are quoted, it was possible to retrospectively calculate forces to failure. This enabled mean force to failure values to be determined from data from two previous bond strength studies as 158.08 N, 17 which is higher than the mean force to failure values achieved in the current study (90.34 N to 130.17 N), and 128.47 N, 18 which is comparable with findings of the current study.…”
Section: Discussionsupporting
confidence: 81%
“…The mean bond strengths reported in the current study (4.60 to 6.01 MPa) compare favorably with those documented in previous research, which quoted means in the range of 3.04 to 7.65 MPa. 17,18,20 Tube D had the least contoured base surface compared with the other three groups. This may have resulted in decreased thickness of adhesive between the base and the substrate, and may have contributed to the higher bond strength.…”
Section: Discussionmentioning
confidence: 89%
See 1 more Smart Citation
“…11 Due to high absorption of Er,Cr:YSGG in both water and hydroxyapatite, it can be used in both oral soft and hard tissues. 12 Absorption in water makes this laser inert relative to ceramic materials and is used when differential removal of a material from ceramic surfaces is intended.…”
mentioning
confidence: 99%
“…Atualmente, o procedimento mais tradicional é o condicionamento com ácido fosfórico (Waveren Hogervorst et al, 2000;Canay et al, 2000;Medhi et al, 2009;Brauchli et al, 2010;Türköz;Ulusoy, 2012); entretanto, com o propósito de obter melhores forças adesivas preservando a integridade do esmalte, outros métodos de condicionamento têm sido propostos, como diferentes ácidos (ácido sulfúrico diluído, ácido maleico e ácido poliacrílico) (Ärtun;Bergland, 1984;Olsen et al, 1997b;Bishara et al, 2000), laser de alta potência (Berk et al, 2008;Türköz;Ulusoy, 2012), self etching primers (Halpern;Rouleau, 2010;Türköz;Ulusoy, 2012) e jato de óxido de alumínio (Olsen et al, 1997a;Reisner et al, 1997;Canay et al, 2000;Berk et al, 2008;Medhi et al, 2009;Brauchli et al, 2010;Halpern;Rouleau, 2010, Cal-Neto et al, 2011Suma et al, 2012;Türköz;Ulusoy, 2012).…”