2023
DOI: 10.1111/jce.16101
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of pulsed‐field ablation versus very high power short duration‐ablation for pulmonary vein isolation

Jonas Wörmann,
Jan‐Hendrik Schipper,
Jakob Lüker
et al.

Abstract: BackgroundThe newly introduced nonthermal pulsed field ablation (PFA) is a promising technology to achieve fast pulmonary vein isolation (PVI) with high acute success rates and good safety features. However, previous studies have shown that very high power short duration ablation (VHPSD) is also highly effective and fast to achieve PVI with potentially less arrhythmia recurrence compared to conventional radiofrequency ablation. Data comparing PFA to VHPSD‐PVI is lacking.ObjectiveThis study compared procedural … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 34 publications
0
3
0
Order By: Relevance
“…Compared to both cryoballoon and RFC ablation, PFA significantly reduced procedure times in two non-randomized single-centre studies. 16 , 17 In the only randomized study investigating PFA vs. thermal ablation, PVI procedure duration with PFA was 105.8 ± 29.4 min and 123.1 ± 42.1 min using thermal ablation. 18 …”
Section: Discussionmentioning
confidence: 99%
“…Compared to both cryoballoon and RFC ablation, PFA significantly reduced procedure times in two non-randomized single-centre studies. 16 , 17 In the only randomized study investigating PFA vs. thermal ablation, PVI procedure duration with PFA was 105.8 ± 29.4 min and 123.1 ± 42.1 min using thermal ablation. 18 …”
Section: Discussionmentioning
confidence: 99%
“…This possible cause has been extensively discussed before. 20 , 22 , 31 Therefore, practice changed resulting in abandoning the use of this certain guidewire and the use of a J-tip guidewire instead. After switching to the J-tip guidewire, no further tamponades occurred in the PFA group.…”
Section: Discussionmentioning
confidence: 99%
“…A fixed‐effect model was employed in cases of low heterogeneity; otherwise, a random‐effect model was used. We also planned a priori subgroup analysis based on (i) type of AF (paroxysmal, persistent), (ii) studies using ≥70 W and <70 W power in the HPSD group (the term “70 W/5 s” is commonly regarded as a very HSPD in various literature 14,15 ), (iii) studies using contact force sensing ablation catheters, and (iv) studies with ablation lesions in extra‐PV. Sensitivity analysis was also conducted based on the ablation of extra‐PV lesions (this may result in an elevation of both fluoroscopy and procedure duration) and a study that demonstrated a significant advantage for CBA patients 16 .…”
Section: Methodsmentioning
confidence: 99%