IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468)
DOI: 10.1109/iecon.2003.1280206
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of prospective topologies for aircraft autotratisformer-rectifier units

Abstract: Abstrnci -This paper explores the feasibility of employing 18-pulse Autotransformer Rectifier Units (ATRUs) for more electric aircrafts, thus expanding the usage of these converters onto variable, high frequency applications. Brticularly, the paper presents a detailed comparison of three 18-pulse ATRUs, based on input ac harmonic current distortion, output voltage regulation, common mode voltage, impact of impedance mismatch behveen rectifier paths and impact of iupnt voltage harmonic distortion. The compariso… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 36 publications
(13 citation statements)
references
References 21 publications
0
13
0
Order By: Relevance
“…A distinguishing feature is that constant-frequency generators are to be replaced by variable-frequency generators to eliminate complexities associated with the integrated mechanical frequency controller of generators [1]. With the generated voltages and frequencies subject to significant tolerance, power electronics is to maintain the load voltages as required [2].…”
Section: Introductionmentioning
confidence: 99%
“…A distinguishing feature is that constant-frequency generators are to be replaced by variable-frequency generators to eliminate complexities associated with the integrated mechanical frequency controller of generators [1]. With the generated voltages and frequencies subject to significant tolerance, power electronics is to maintain the load voltages as required [2].…”
Section: Introductionmentioning
confidence: 99%
“…A multi-pulse rectifier is a rectifier composed of diode rectifiers connected in parallel through a phase-shifting transformer to provide inherent high power factor and low THD. So far, Energies 2018, 11, 379 3 of 17 multi-pulse rectifier technology is highly used in aircraft power system, the fundamental frequency of which is 360-800 Hz and very good for reducing the volume and weight of transformer [15][16][17]. However, in WECS application, considering the quite low rotor speed, i.e., low fundamental frequency, the volume and weight of the transformer might be increased dramatically if the conventional multi-pulse technology had still been adopted.…”
Section: Introductionmentioning
confidence: 99%
“…Among possible 18-pulse Autotransformer-Rectifier-Unit (ATRU) topologies, Direct Symmetric circuit (DS-ATRU) demonstrates relatively low complexity, is insensitive to impedance mismatch and distortions of the input voltage and has low common mode voltage [17]. Due to these reasons, 18-pulse DS-ATRU is a logical choice for passive rectification for the aircraft application.…”
Section: Introductionmentioning
confidence: 99%