2023
DOI: 10.3390/jvd2030026
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Performance of Micro-Computed Tomography (Micro-CT) and Synchrotron Radiation CT in Assessing Coronary Stenosis Caused by Calcified Plaques in Coronary Artery Phantoms

Curtise K. C. Ng,
Zhonghua Sun,
Shirley Jansen

Abstract: Synchrotron-radiation-computed tomography (SRCT) allows more accurate calcified plaque and coronary stenosis assessment as a result of its superior spatial resolution; however, typical micro-computed tomography (micro-CT) systems have even higher resolution. The purpose of this study was to compare the performance of high-resolution micro-CT with SRCT in the assessment of calcified plaques and a previously published dataset of coronary stenosis assessment. This experimental study involved micro-CT scanning of … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 61 publications
(115 reference statements)
0
1
0
Order By: Relevance
“…Various approaches have been proposed to address the issues encountered in coronary plaques, such as the use of image post-processing methods, iterative reconstruction, and thin slice thicknesses, as well as the use of AI algorithms [79][80][81][82][83][84][85][86][87][88][89]. This has improved coronary CTA performance to some extent; however, the specificity and PPV are still mod-erate (less than 70%) [88][89][90][91][92][93]. The recent advancements in CT technology and specifically the emergence of photon-counting CT have overcome this limitation to a greater extent, with superior spatial resolution and multi-energy imaging characteristics contributing to improving the diagnostic value [21][22][23][24][25][26][27][28].…”
Section: Cardiovascular Ct: Diagnostic Value Based On Standard Imagin...mentioning
confidence: 99%
“…Various approaches have been proposed to address the issues encountered in coronary plaques, such as the use of image post-processing methods, iterative reconstruction, and thin slice thicknesses, as well as the use of AI algorithms [79][80][81][82][83][84][85][86][87][88][89]. This has improved coronary CTA performance to some extent; however, the specificity and PPV are still mod-erate (less than 70%) [88][89][90][91][92][93]. The recent advancements in CT technology and specifically the emergence of photon-counting CT have overcome this limitation to a greater extent, with superior spatial resolution and multi-energy imaging characteristics contributing to improving the diagnostic value [21][22][23][24][25][26][27][28].…”
Section: Cardiovascular Ct: Diagnostic Value Based On Standard Imagin...mentioning
confidence: 99%