Comparison of Patient Preference for Two Insulin Injection Pen Devices in Relation to Patient Dexterity Skills

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
22
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 33 publications
(24 citation statements)
references
References 18 publications
2
22
0
Order By: Relevance
“…Some formal summative testing of a given device across the intended user groups in the selected indication has also been reported 20,21. With regard to formative testing with the intent of identifying potential hazards and providing design input, only limited work on pen injectors can be found in the literature 14,15. To our knowledge, no studies involving users selected to be applicable across different indications have been published.…”
Section: Introductionmentioning
confidence: 99%
“…Some formal summative testing of a given device across the intended user groups in the selected indication has also been reported 20,21. With regard to formative testing with the intent of identifying potential hazards and providing design input, only limited work on pen injectors can be found in the literature 14,15. To our knowledge, no studies involving users selected to be applicable across different indications have been published.…”
Section: Introductionmentioning
confidence: 99%
“…This highlights that participants had a positive perception of the shield‐triggered mechanism. Previous design modifications aimed at improving the ease of pen‐injector handling and use have had a positive impact on patient confidence and preference, especially among those with impaired manual dexterity . In addition, the shield of the DV3316 hides the needle during injection, which in a similar manner to contact‐activated figure puncture lancets, may help alleviate anxiety in some people and enhance user acceptabilty .…”
Section: Discussionmentioning
confidence: 99%
“…the needle into the skin, users must fully depress the dose button and wait for several seconds after the end-of-dose click or until the dose counter has returned to zero before withdrawing the needle from the skin. Issues associated with most pen-injectors include difficulty depressing the extended-dose button, especially among young patients or patients with impaired manual dexterity, strength or nerve function, 9,10 and premature needle withdrawal, leading to underdelivery of dose. 11,12 DV3316 is a prototype multiple-use pen-injector with a shieldtriggered injection mechanism developed by Novo Nordisk A/S.…”
mentioning
confidence: 99%
“…In summary, the study completed by Pfützner and colleagues 26 is one of the first to investigate preference and usability of pen devices in patients with visual and dexterity limitations. Future studies of diabetes technology should follow suit, as they provide health care professionals with a better understanding of how to best care for patients with these special needs.…”
Section: The First Insulin Pen Was Introduced In the Unitedmentioning
confidence: 99%
“…26 The investigators' primary objective was to determine if patient preference is influenced by dexterity skills, with and without visual limitations. The secondary objectives included the impact of dexterity and cognitive function on ability to use the devices correctly.…”
Section: The First Insulin Pen Was Introduced In the Unitedmentioning
confidence: 99%