Comparison of Omega Wave System and Polar S810i to Detect R-R Intervals at Rest

Abstract: The present study was performed to compare R-R interval data and heart rate variability indices obtained from the Polar S810i and the Omega Wave Sport System for a total of 96 adults in a supine position. Data were simultaneously recorded with the Polar S810i and the Omega Wave Sport System and processed by unique software. Bland-Altman analysis for the R-R intervals shows minimal bias for free and paced breathing. No significant differences were observed for heart rate variability indices derived from the sig… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
27
0
1

Year Published

2012
2012
2024
2024

Publication Types

Select...
8
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 36 publications
(30 citation statements)
references
References 23 publications
1
27
0
1
Order By: Relevance
“…Heart rate and RR intervals were registered beat-to-beat, through a heart rate monitor (Polar S810i) with a 1000 Hz sampling frequency, fastened by an elastic band across chest in heart level. Polar S810i is a valid method to record RR interval and to obtain a valid analysis of HRV (Parrodo et al 2010). Analysis of HRV measurements were conducted with the aid of Kubios HRV Analysis Software 2.1 (MATLAB, the Biomedical Signal Analysis Group, University of Kuopio, Kuopio, Finland) and data interpretation was M A N U S C R I P T ACCEPTED MANUSCRIPT made on basis of previous researches (Huang et al 2009;Wang & Huang 2012).…”
Section: Experimental Condition and Protocolmentioning
confidence: 99%
“…Heart rate and RR intervals were registered beat-to-beat, through a heart rate monitor (Polar S810i) with a 1000 Hz sampling frequency, fastened by an elastic band across chest in heart level. Polar S810i is a valid method to record RR interval and to obtain a valid analysis of HRV (Parrodo et al 2010). Analysis of HRV measurements were conducted with the aid of Kubios HRV Analysis Software 2.1 (MATLAB, the Biomedical Signal Analysis Group, University of Kuopio, Kuopio, Finland) and data interpretation was M A N U S C R I P T ACCEPTED MANUSCRIPT made on basis of previous researches (Huang et al 2009;Wang & Huang 2012).…”
Section: Experimental Condition and Protocolmentioning
confidence: 99%
“…This allowed us to check linearity between these two systems. 23 Recordings were transferred via infrared port to a specific data processing program 24 (Polar Precision 24 Performance Software v.4.03.050, Polar Electro Oy, Kempele, Finland). Once viewed on the notebook screen, the data were filtered to remove any interference.…”
Section: Heart Rate Variabilitymentioning
confidence: 99%
“…While the collection of (beat-by-beat) HR was initially only possible with expensive laboratory-based electrocardiograph recorders, the recent availability of valid and portable recorders such as heart-rate monitors (Gamelin et al, 2006; Weippert et al, 2010; Wallen et al, 2012), specifically-designed systems (Parrado et al, 2010; Cassirame et al, 2013) or smart phone applications (Flatt and Esco, 2013) has substantially boosted the use of HRV monitoring in the field. However, despite its common implementation in the field, HR monitoring is still not accepted as a gold standard, likely due to the lack of consistency in the literature.…”
Section: Introductionmentioning