1998
DOI: 10.1161/01.str.29.10.2032
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Near-Infrared Spectroscopy and Somatosensory Evoked Potentials for the Detection of Cerebral Ischemia During Carotid Endarterectomy

Abstract: Background and Purpose-We sought to assess the clinical value of regional cerebral saturation (rSO 2 ) obtained by means of the cerebral oximeter INVOS 3100A (Somanetics) in comparison to monitoring of somatosensory evoked potentials (SEP) for the reliable detection of severe cerebral ischemia requiring shunt placement in the individual patient undergoing carotid surgery under general anesthesia. Methods-In 317 patients undergoing reconstructive surgery on the internal carotid artery, simultaneous recordings o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
49
1
6

Year Published

2007
2007
2022
2022

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 106 publications
(60 citation statements)
references
References 41 publications
4
49
1
6
Order By: Relevance
“…Twenty-five patients were monitored throughout the neurosurgery. In all cases with evidence of ischemic events (brain edema, slowing of electroencephalography, postoperative stroke, and failure of balloon occlusion testing), there was a decrease in HbO 2 and tHb concentrations and brain tissue SO 2 , with an increase in HHb concentrations.…”
Section: Neuromonitoring Methodsmentioning
confidence: 97%
See 2 more Smart Citations
“…Twenty-five patients were monitored throughout the neurosurgery. In all cases with evidence of ischemic events (brain edema, slowing of electroencephalography, postoperative stroke, and failure of balloon occlusion testing), there was a decrease in HbO 2 and tHb concentrations and brain tissue SO 2 , with an increase in HHb concentrations.…”
Section: Neuromonitoring Methodsmentioning
confidence: 97%
“…Calderon-Arnulphi et al 2 , and HHb during a right CEA. Oxygenation baseline was lower on the affected side.…”
Section: Case 25mentioning
confidence: 94%
See 1 more Smart Citation
“…However, it still carries a 5-7.5% risk of perioperative cerebral infarction (14). The main reason for cerebrovascular events is hypoperfusion during carotid clamping.…”
Section: Discussionmentioning
confidence: 99%
“…When compared with SPECT, the sensitivity and specificity of transcranial regional cerebral oxygen saturation for the detection of hyperperfusion were 100%. Transcranial near-infrared spectroscopy can demonstrate decreased cerebral oxygenation resulting from ICA clamping (Beese et al, 1998;Duncan et al, 1995;Kirkpatrick et al, 1995;Samra et al, 1996) and can predict post-CEA CHS. Matsumoto et al (2009) used transcranial near-infrared spectroscopy to study 64 patients undergoing CAS, two of whom developed CHS (diagnosed by increased CBF at SPECT the day after treatment).…”
Section: Diagnosing Cerebral Hyperperfusionmentioning
confidence: 99%