Comparison of Monopolar Electrocoagulation, Bipolar Electrocoagulation, Ultracision, and Ligasure

Abstract: LS and UC are clearly the safest and most efficient methods of coagulation, whereas ME and BE could cause serious clinical and histological complications. We found histological evidence that UC causes a slightly greater inflammatory response than LS, and the clinical implications of this warrant further investigation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
140
2
3

Year Published

2007
2007
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 149 publications
(149 citation statements)
references
References 32 publications
4
140
2
3
Order By: Relevance
“…The output is feedbackcontrolled so that a reliable seal is achieved in minimal time, independently of the type or amount of tissue in the jaws. The thermal spread is significantly less than with traditional bipolar systems and comparable with that of ultrasonic coagulation [23].…”
Section: Discussionmentioning
confidence: 83%
See 1 more Smart Citation
“…The output is feedbackcontrolled so that a reliable seal is achieved in minimal time, independently of the type or amount of tissue in the jaws. The thermal spread is significantly less than with traditional bipolar systems and comparable with that of ultrasonic coagulation [23].…”
Section: Discussionmentioning
confidence: 83%
“…All the studies were read in their entirety to assess their appropriateness for inclusion in the metaanalysis. All studies that compared EBVS and UE in an experimental setting [23], EBVS/UE with other energy sources [24,25], or two instruments for dissection and vessel sealing [26] in laparoscopic colorectal surgery were included in the metaanalysis.…”
Section: Methodsmentioning
confidence: 99%
“…Additionally, UC created less full-thickness damage in the bladder, peritoneum, stomach, and colonic tissues. In contrast, Diamantis et al [23] compared the effects of UC and BP on rabbits' short gastric vessels. They reported greater thermal injury and inflammatory response after UC than after BP during the second postoperative week.…”
Section: Discussionmentioning
confidence: 98%
“…Minimizing thermal damage to surrounding tissues without compromising safety and tissue integrity is of importance in surgery. Ultrasonic instruments are tried to be safer than traditional diathermy [7,20,[24][25][26]. The Ultrasonic shears incorporate piezoelectric transducers that induce a vibration frequency at the functional tip and transduces a lower amount of energy to the tissue than high-frequency current or laser techniques, resulting in reduced lateral thermal damage and penetration depth owing to lower temperatures [7,20,27].…”
Section: Thermal Damage In Laparoscopy-an In-depth Reviewmentioning
confidence: 99%
“…Both technologically advanced, they have been suggested to have excellent results and minimal lateral thermal injury. [6,7,18,20,24,26]. Laparoscopic ultrasonic instruments obtain the same cutting and coagulation objectives but in different manners.…”
Section: Thermal Damage In Laparoscopy-an In-depth Reviewmentioning
confidence: 99%