2012
DOI: 10.5792/ksrr.2012.24.1.25
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Mobile-Bearing and Fixed-Bearing Designs in High Flexion Total Knee Arthroplasty: Using a Navigation System

Abstract: PurposeWe compared and analyzed the short term results of high flexion total knee arthroplasty (TKA) with mobile-bearing and fixed bearing designs.Materials and MethodsWe studied 32 patients that had undergone TKA with LPS-Flex Mobile and 34 patients with LPS-Flex Fixed using an electromagnetic navigation system between January 2010 and June 2010, and were followed up for at least 1 year.ResultsKnee Society Functional Score (KSFS) and Knee Society Knee Score (KSKS) of the mobile-bearing group were 94.5 and 93.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
14
2

Year Published

2013
2013
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(17 citation statements)
references
References 24 publications
1
14
2
Order By: Relevance
“…Our experience was that in the presence of ferrous materials the system would go 'blind' and prior to loss of signal, no unexplained change in the system readout values was noted. Other in vitro and in vivo studies looking at the results of electromagnetic navigation have confirmed that system accuracy is not problematic, with good results comparable to infra-red systems [35,40,41]. Two clinical studies have compared the electromagnetic technique directly with traditional infra-red navigation systems and found similar, high degrees of accuracy [42,43], although the numbers in these studies were small.…”
Section: Discussionmentioning
confidence: 86%
“…Our experience was that in the presence of ferrous materials the system would go 'blind' and prior to loss of signal, no unexplained change in the system readout values was noted. Other in vitro and in vivo studies looking at the results of electromagnetic navigation have confirmed that system accuracy is not problematic, with good results comparable to infra-red systems [35,40,41]. Two clinical studies have compared the electromagnetic technique directly with traditional infra-red navigation systems and found similar, high degrees of accuracy [42,43], although the numbers in these studies were small.…”
Section: Discussionmentioning
confidence: 86%
“…In high-flexion prostheses, Kim et al [16] reported no differences in clinical and radiological parameters, range of motion and maximum flexion angle at a follow-up of a year.…”
Section: Discussionmentioning
confidence: 97%
“…Of these, we included 34 clinical trials with 4754 patients (6861 TKRs) in the meta-analysis. [4][5][6][7][11][12][13][14][15][16][17][18][19] There were 32 RCTs, two were CCTs, 6,29 and two were from the same trial. 23,41 The characteristics of the studies that were included are shown in Tables I and II.…”
Section: Methodsmentioning
confidence: 99%
“…[3][4][5][6][7][8][9][10] However, these studies focused on the clinical outcome and did not evaluate the polyethylene wear and prosthetic survivorship, including radiolucent lines, osteolysis, aseptic loosening and the rate of revision. 3,[8][9][10] In all, nine RCTs comparing outcomes of these two designs were published in 2012, [11][12][13][14][15][16][17][18][19] without conclusive results.…”
mentioning
confidence: 98%