2022
DOI: 10.1016/j.jpba.2022.114823
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of methods for quantitative analysis of ranibizumab and bevacizumab in human plasma using various bioanalytical techniques, including microfluidic immunoassay, triple quadrupole, and high-resolution liquid chromatography-tandem mass spectrometry approaches

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 22 publications
0
3
0
Order By: Relevance
“…Additionally, they require personnel (although, the "new" MALDI-ToF does not) with specialized training, and, due to batch processing, tend to have longer turnaround times (which has been successfully reduced). In contrast, immunoassays tend to be more easily automated and require less training but are more susceptible to interference and can require higher-priced reagents, hence costing more to run [36,69,74,75]. On the other hand, the cost of running LC-MS practically does not exist, however financial considerations for purchasing an MS are substantial.…”
Section: Feasibilitymentioning
confidence: 99%
“…Additionally, they require personnel (although, the "new" MALDI-ToF does not) with specialized training, and, due to batch processing, tend to have longer turnaround times (which has been successfully reduced). In contrast, immunoassays tend to be more easily automated and require less training but are more susceptible to interference and can require higher-priced reagents, hence costing more to run [36,69,74,75]. On the other hand, the cost of running LC-MS practically does not exist, however financial considerations for purchasing an MS are substantial.…”
Section: Feasibilitymentioning
confidence: 99%
“…Additionally, they require personnel (although, the "new" MALDI-ToF does not) with specialized training, and, due to batch processing, tend to have longer turnaround times (which has been successfully reduced). In contrast, immunoassays tend to be more easily automated and require less training but are more susceptible to interference and can require higher-priced reagents, hence costing more to run [35,64,69,70].…”
Section: Feasibilitymentioning
confidence: 99%
“…In the last two decades, protein Aor G-coated magnetic beads have become commercially available and have been widely used as a purication method in the quantication of mAbs by LC-MS/MS. 17,25,29,37,38 They interact with the Fc region (CH 2 -CH 3 interface) and Fab region (VH domain for protein A and CH 1 for protein G). However, peptostreptococcal protein L, a surface Ig-binding protein from Peptostreptococcus magnus, does not interfere with the Fc region.…”
Section: Introductionmentioning