2021
DOI: 10.1016/j.ajo.2020.11.005
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Methods for Measuring Cyclodeviation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…Although there have been efforts to extract cyclodeviation from fundus images (15,16), sensory measurements using DMR remain the gold standard, comparable with synoptophore measurements which require a bulky desktop device (4). Sensory techniques have previously been used to obtain cyclodeviation measurements using a desktop display (16) or smartphone app (14) coupled with red/green glasses to isolate the inputs to each eye.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Although there have been efforts to extract cyclodeviation from fundus images (15,16), sensory measurements using DMR remain the gold standard, comparable with synoptophore measurements which require a bulky desktop device (4). Sensory techniques have previously been used to obtain cyclodeviation measurements using a desktop display (16) or smartphone app (14) coupled with red/green glasses to isolate the inputs to each eye.…”
Section: Discussionmentioning
confidence: 99%
“…It is performed by placing lenses that refract a point light source into a line image in front of each eye. The patient is asked to rotate the lenses, so the lines are perceived to be parallel to each other (4). Measurements are imprecise and prone to administrator error (5).…”
Section: Introductionmentioning
confidence: 99%
“…Objective deviations were evaluated (to test whether the patient was able to fuse at the objective angle) using a traditional synoptophore (Oculus, Wetzlar, Germany), and a modern version based on virtual reality glasses with an eye tracker (VisionaryVR; VisionaryTool S.L., Gijón, Spain). Deviations in cyclotorsion were measured with both synoptophore devices in addition to a Double Maddox rod test ( Liebermann et al, 2021 ).…”
Section: Methodsmentioning
confidence: 99%
“…The actions of the various extraocular muscles are generally not independent, and with incomitant strabismus, the direction and extent of misalignment may vary significantly with the gaze direction 5 . Measurement of eye misalignment in strabismic patients may be performed by orthoptists or optometrists using various instruments, including refracting prisms, the double Maddox rod, and the synoptophore, 6 the latter two being able to measure torsional misalignment.…”
mentioning
confidence: 99%