1999
DOI: 10.1118/1.598602
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of methods for instantaneous angiographic blood flow measurement

Abstract: Several different algorithms have been reported for measurement of blood flow rates and velocities from digital x-ray angiograms. We compare four videodensitometric methods: (1) distance-density curve matching (DDCM), (2) distance-density curve matching with curve-fitting (DDCM-F), (3) bolus mass tracking with curve-fitting (BMT-F) and (4) fluid continuity method (FCM). We tested the flow algorithms with simulated angiograms and with images obtained from a programmable flow phantom under clinically realistic f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2000
2000
2014
2014

Publication Types

Select...
3
2
1

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 31 publications
0
6
0
Order By: Relevance
“…A similar method was used to compute flow velocity in a flow phantom by Hoffmann et al 122 This algorithm has been found to have performance superior to that of the bolus mass tracking approach, 117 but later research did not support that observation. 123 That disparity was explained by the differences between the implementations of the algorithms and between the parameters of measured flows. 123 The process of finding the optimal match of shifted distance-density curves is similar to mathematical crosscorrelation used in the cross-correlation of time-density curves method ͑Sec.…”
Section: Velocity Determination From Distance-density Curve Shiftsmentioning
confidence: 99%
See 2 more Smart Citations
“…A similar method was used to compute flow velocity in a flow phantom by Hoffmann et al 122 This algorithm has been found to have performance superior to that of the bolus mass tracking approach, 117 but later research did not support that observation. 123 That disparity was explained by the differences between the implementations of the algorithms and between the parameters of measured flows. 123 The process of finding the optimal match of shifted distance-density curves is similar to mathematical crosscorrelation used in the cross-correlation of time-density curves method ͑Sec.…”
Section: Velocity Determination From Distance-density Curve Shiftsmentioning
confidence: 99%
“…123 That disparity was explained by the differences between the implementations of the algorithms and between the parameters of measured flows. 123 The process of finding the optimal match of shifted distance-density curves is similar to mathematical crosscorrelation used in the cross-correlation of time-density curves method ͑Sec. III A 2͒.…”
Section: Velocity Determination From Distance-density Curve Shiftsmentioning
confidence: 99%
See 1 more Smart Citation
“…The method is a combination of our prior demonstrations of functional angiography [10] and blood velocity [4] calculations in 4D CT, which were based upon videodensitometric methods first described in conventional angiography and have been extensively reviewed [11,12].…”
Section: Introductionmentioning
confidence: 99%
“…-Techniques based on measuring the distance that contrast medium travels between two frames [3,2]. -Optical flow based methods [4,5,2].…”
Section: Introductionmentioning
confidence: 99%