Comparison of MERV 16 and HEPA filters for cab filtration of underground mining equipment

Abstract: Significant strides have been made in optimizing the design of filtration and pressurization systems used on the enclosed cabs of mobile mining equipment to reduce respirable dust and provide the best air quality to the equipment operators. Considering all of the advances made in this area, one aspect that still needed to be evaluated was a comparison of the efficiencies of the different filters used in these systems. As high-efficiency particulate arrestance (HEPA) filters provide the highest filtering effici… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
42
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(42 citation statements)
references
References 1 publication
(3 reference statements)
0
42
0
Order By: Relevance
“…We observed accumulated dust inside the cab. Recent NIOSH studies have shown that an effective vehicle cab filtration system includes both a powered and pressurized air intake as well as filtered circulation air to reduce respirable dust [Cecala et al 2012;Organiscak et al 2013;Cecala et al 2014]. The ventilation system on the Bobcat Skid Steer was not powered, and there was no change-out schedule for its air filters.…”
Section: Observationsmentioning
confidence: 99%
“…We observed accumulated dust inside the cab. Recent NIOSH studies have shown that an effective vehicle cab filtration system includes both a powered and pressurized air intake as well as filtered circulation air to reduce respirable dust [Cecala et al 2012;Organiscak et al 2013;Cecala et al 2014]. The ventilation system on the Bobcat Skid Steer was not powered, and there was no change-out schedule for its air filters.…”
Section: Observationsmentioning
confidence: 99%
“…This study was conducted on enclosed cabs on both an underground face drill and a roof bolter using particle counting test methods between shifts in order to benchmark protection factor performance under consistent operating procedures. Airflow and cab pressure measurements made on these cabs during this long-term study, including several other filter combinations tested, showed that multiple leakages around the filters in the HVAC system had a noticeable impact on the overall cab's PF performance, and that these additional leakages could be incorporated into mathematical modeling of these filtration systems [Cecala et al 2016].…”
Section: Introductionmentioning
confidence: 95%
“…The performance of this cab filtration system design was further studied in the field on several pieces of underground mining equipment. Underground dust and diesel field sampling results during a seven-month field study showed inconsistent cab PFs among production shifts because of unpredictable equipment operator practices, such as the frequency and duration of opening the cab door and the variability in HVAC system operation [Cecala et al 2012;Noll et al 2014a]. Particle counting and HVAC airflow measurements made on these cabs in ambient air outside the mine between production shifts provided a better quantification or benchmarking of their optimum long-term PF performance under consistent near steady state cab testing conditions, termed "static testing" [Cecala et al 2012;Organiscak et al 2013].…”
Section: Introductionmentioning
confidence: 99%