2019
DOI: 10.1007/s10157-019-01712-x
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of measurements of anti-PLA2R antibodies in Japanese patients with membranous nephropathy using in-house and commercial ELISA

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 27 publications
0
10
0
Order By: Relevance
“…The mechanisms of MN with solitary polyclonal IgA deposition in the previously reported case and the present case are unknown. In the present case, circulating IgA-class anti-PLA2R antibodies were not detected by our in-house ELISA [7]. Other known autoantigens in patients with primary MN [1] or exogenous mucosal antigens, such as bacterial antigens, may be associated with solitary polyclonal IgA deposition with MN features.…”
Section: Discussionmentioning
confidence: 58%
See 1 more Smart Citation
“…The mechanisms of MN with solitary polyclonal IgA deposition in the previously reported case and the present case are unknown. In the present case, circulating IgA-class anti-PLA2R antibodies were not detected by our in-house ELISA [7]. Other known autoantigens in patients with primary MN [1] or exogenous mucosal antigens, such as bacterial antigens, may be associated with solitary polyclonal IgA deposition with MN features.…”
Section: Discussionmentioning
confidence: 58%
“…Monoclonal proteins were not detected in the serum or urine. Circulating IgA-class anti-PLA2R antibodies were not determined by our in-house ELISA [7] using peroxidase-conjugated anti-human IgA as a secondary antibody.…”
Section: Case Reportmentioning
confidence: 99%
“…At 20 RU/ml, the average sensitivity was 65.5% with 98.4% specificity [12,17,20,21,24,25]. At a cut-off value of 14 RU/ ml, average sensitivity and specificity were 69.1% and 95.2%, respectively [12,20,26,27]. Finally, in the studies in which the authors, based on ROC curves, opted for much lower cutoffs (between 2.0 and 2.7 RU/ml), the average sensitivity was 81.8% and the specificity was 93.8% [20-22, 28, 29].…”
Section: Discussionmentioning
confidence: 97%
“…The estimated glomerular ltration rate was calculated using the formula for Japanese patients 24 . Circulating PLA2R Abs were measured in pMN patients using enzyme-linked immunosorbent assay (ELISA), in-house ELISA, and a standardized commercial ELISA (Euroimmun, Lübeck, Germany), as described previously 25 .…”
Section: Methodsmentioning
confidence: 99%