Comparison of Macular Thickness Measurements between Time Domain and Spectral Domain Optical Coherence Tomography

Abstract: Although both time domain and spectral domain OCTs are reliable for macular thickness measurements, spectral domain OCT has better measurement repeatability compared with time domain OCT. Macular measurements obtained from the two OCT systems may not be used interchangeably.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

7
131
5
12

Year Published

2008
2008
2020
2020

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 202 publications
(155 citation statements)
references
References 13 publications
7
131
5
12
Order By: Relevance
“…The ratio between MT measured with SD-SLO/OCT and TD-OCT was 1.1, whereas it has resulted to be 1.01 in case of a different SD-OCT device. 13 However, our data show that the different OCT acquisition systems determine different retinal thickness measurements but scarcely influence retinal volume measurements.…”
Section: Discussionmentioning
confidence: 67%
See 2 more Smart Citations
“…The ratio between MT measured with SD-SLO/OCT and TD-OCT was 1.1, whereas it has resulted to be 1.01 in case of a different SD-OCT device. 13 However, our data show that the different OCT acquisition systems determine different retinal thickness measurements but scarcely influence retinal volume measurements.…”
Section: Discussionmentioning
confidence: 67%
“…The poor agreement between Stratus OCT and a different spectral domain OCT (3D OCT, Topcon, Tokyo, Japan) has already been reported. 13 Although this was limited to normal eyes, it resulted in a SD-OCT/ TD-OCT ratio of 1.01 and a correlation between the amount of difference and the thickness was not suggested. To obtain retinal thickness measurement, Stratus OCT uses segmentation algorithms to mark the ILM as the inner boundary and the inner segment/outer segment junction (IS/OS) as the outer boundary.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Leung et al 12 reported the 95% limits of agreement between Stratus and 3D-OCT to be 3.9-37.8 mm. Such poor agreements are considered too large to allow devices to be used interchangeably.…”
Section: Eyes With Dmementioning
confidence: 99%
“…Günümüzde küçük kesili modern katarakt ameliyatına rağmen diyabetik hastalarda, ameliyat sonrası dönemde maküla değişiklikleri görülmektedir. [4][5][6] Otani ve ark. [7] santral maküler kalınlık ile en iyi düzel-tilmiş görme keskinliği arasında negatif ve zayıf bir korelasyon olduğunu saptamışlardır.…”