2017
DOI: 10.1016/j.clinimag.2017.01.017
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of low-dose coronary artery calcium scoring using low tube current technique and hybrid iterative reconstruction vs. filtered back projection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 20 publications
0
9
0
Order By: Relevance
“…Recent innovations in CT techniques have enabled reconstruction algorithms supplied by various vendors and by lowering the tube voltage/current to be extensively investigated in coronary CT angiography (CTA) (6,7). However, the reference protocol for CAC acquisition still requires 120 kVp presetting and filter back projection (FBP) reconstruction (8), and there are considerable concerns about medical radiation exposure and its resultant cancer risk (9,10).…”
Section: Coronary Calcium Scoring Has Become a Common Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Recent innovations in CT techniques have enabled reconstruction algorithms supplied by various vendors and by lowering the tube voltage/current to be extensively investigated in coronary CT angiography (CTA) (6,7). However, the reference protocol for CAC acquisition still requires 120 kVp presetting and filter back projection (FBP) reconstruction (8), and there are considerable concerns about medical radiation exposure and its resultant cancer risk (9,10).…”
Section: Coronary Calcium Scoring Has Become a Common Methodsmentioning
confidence: 99%
“…Post-hoc analysis showed significant differences between the five techniques (all P<0.05). The median mass scores were 32 [7,63], 29 [6,61], 31 [6.5, 63], 30 [6.5, 59], and 30 [6.5, 59] mg for FBP, ASIR-V 50%, DLIR-L, DLIR-M, and DLIR-H, respectively. Post-hoc analysis revealed that ASIR-V and three DLIR reconstruction levels differed significantly from FBP in mass score (all P<0.05).…”
Section: Cac Scoringmentioning
confidence: 99%
“…ASIR-V allows for more advanced modeling because it deemphasizes the system optics modeling, enabling reconstruction speeds similar to those of filtered backprojection. Because ASIR-V was used on both systems, the dose reduction associated with use of 256-row scanning is incremental to this technique (14). With the new-generation 256-row CT scanner along with accompanying protocols, we are able to perform CCTA at significantly lower radiation doses.…”
Section: Discussionmentioning
confidence: 99%
“…With innovations in CT techniques, reconstruction algorithms by various vendors and lowering tube voltage / tube current has been extensively investigated in CT coronary angiography [4][5]. however, CAC acquisition protocol still needs to be preset in 120kVp and reconstructed by filter back projection (FBP) [6], which lead to a relatively high level of image noise and radiation dose.…”
Section: Introductionmentioning
confidence: 99%