2008
DOI: 10.1016/j.radmeas.2007.12.013
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of LiF (TLD-100 and TLD-100H) detectors for extremity monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
9
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 2 publications
1
9
0
Order By: Relevance
“…The energy dependent response of the thermoluminescent material used in this study (LiF:Mg,Cu,P) was investigated by several groups. [9][10][11][12] Monte Carlo simulations of photon spectra for 6 MV photon beams inside and outside of the primary beam were performed by Edwards and Mountford 13 and by Scarboro et al 14 They showed that the mean energy of the photons was shifted from about 1.5 MeV on the central axis down to about 0.3 MeV outside of the primary beam, close to the field edge.…”
Section: Iig Energy Correctionmentioning
confidence: 99%
“…The energy dependent response of the thermoluminescent material used in this study (LiF:Mg,Cu,P) was investigated by several groups. [9][10][11][12] Monte Carlo simulations of photon spectra for 6 MV photon beams inside and outside of the primary beam were performed by Edwards and Mountford 13 and by Scarboro et al 14 They showed that the mean energy of the photons was shifted from about 1.5 MeV on the central axis down to about 0.3 MeV outside of the primary beam, close to the field edge.…”
Section: Iig Energy Correctionmentioning
confidence: 99%
“…[40][41][42] In this study, we observed a retraction in cultured AT-MSCs with exposure strength of 50 kVp, at all exposure duration (group two, three, and four) (Figure 2). Retraction at the study of Pawitan et al 38 was found as a result of confluence imbalance in the flask; monolayer at the flask periphery and over confluence parts grew upwards, forming multiple layers, due to prolonged culture.…”
Section: Resultsmentioning
confidence: 78%
“…The energy dependent response of the thermoluminescence material used in this study (LiF:Mg,Cu,P), was investigated by several groups. [12][13][14][15] Monte Carlo simulations of photon spectra for photon beams produced by gantry-mounted imaging devices were performed by Ding et al 16 and Ding and Coffey 17 for the Varian OBI and by Downes et al 18 for the Elekta XVI.…”
Section: Methodsmentioning
confidence: 99%