Comparison of Labrum Resistance Force while Pull-Probing In Vivo and Cadaveric Hips

Abstract: Cadaver tissue has been identified as the highest-fidelity anatomical representation in terms of the training for orthopedic surgery, including for arthroscopy of a damaged hip labrum. However, hip labrum stiffness in vivo and in cadavers has not been directly compared. The purpose of this study was to compare in vivo and cadaveric hip labrum stiffness during pull-probing with a force sensor. We measured the resistance force of the hip labrum in ten patients during hip arthroscopy (i.e., in vivo) and compared … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(8 citation statements)
references
References 12 publications
0
8
0
Order By: Relevance
“…Using the sliding aspect with a strain gauge sensor in the probing device, each ACL specimen was pulled vertically to its long axis by one author (TH) ( Figure 1 ). The pulling distance was set to 3 mm in this study, following the method used in previous studies [ 10 , 12 ]. Dedicated software visualized and recorded the three forces in separate graphs in x, y, and z directions (x was the transverse direction; y was the vertical direction (direction of the hook); z was the probe axis).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Using the sliding aspect with a strain gauge sensor in the probing device, each ACL specimen was pulled vertically to its long axis by one author (TH) ( Figure 1 ). The pulling distance was set to 3 mm in this study, following the method used in previous studies [ 10 , 12 ]. Dedicated software visualized and recorded the three forces in separate graphs in x, y, and z directions (x was the transverse direction; y was the vertical direction (direction of the hook); z was the probe axis).…”
Section: Methodsmentioning
confidence: 99%
“…As discussed in [ 6 , 7 , 8 ], its evaluation is imprecise. The current technique for evaluating initial tension is to pull the reconstructed ligament with an arthroscopic probe [ 9 ], in a movement called “probing,” which is then assessed based on the surgeon’s intrinsic sensory feedback, or perception, of the amount of tension [ 10 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Probing is performed during arthroscopic surgeries to identify the injured lesion, instability with gap appearance in the repair area, and repair tension of the soft tissue in the knee [21,22]. Recently, a probing device was developed to assess the hip and knee joints [23,24] quantitatively. This probing device quantitatively measures the resistance of soft tissues with a triaxial force sensor; it has been reported to be useful for measuring some mechanical properties of the joints during arthroscopy [23].…”
Section: Introductionmentioning
confidence: 99%
“…In performing various bearing couple studies on medical implant, four approaches can be used, namely clinical study [ 16 ], experimental testing [ 17 ], mathematical formula [ 18 ], and computational simulation [ 19 ]. In the first approach, the method used are radiographic [ 20 ], computed tomography [ 21 ], and hip analysis suite [ 22 ].…”
Section: Introductionmentioning
confidence: 99%