2003
DOI: 10.7589/0090-3558-39.2.387
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Isoflurane and Sevoflurane for Anesthesia in Beaver

Abstract: We compared the hemodynamic and respiratory effects, recovery time, and cost of two gas inhalants (isoflurane and sevoflurane) for anesthetic induction and maintenance of beaver (Castor canadensis) during surgery to implant radio transmitters in the peritoneal cavity. Heart rate, respiratory rate, relative hemoglobin saturation with oxygen (SpO 2 ), and body temperature were measured every 5 min for the first 45 min, and arterial blood gas was measured once, 25 min into the anesthetic procedure. Induction for … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
6
0

Year Published

2006
2006
2016
2016

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 16 publications
1
6
0
Order By: Relevance
“…Nevertheless, because we used this vaporizer outside its recommended range of temperatures (15 C to 35 C), the reported settings of isoflurane are not necessary equal to the actual concentration delivered. Even though isoflurane has a slightly pungent and ethereal odor and can irritate the upper airways (Calvey and Williams, 2001), martens tolerated induction via face mask well; this is consistent with observations of Siberian polecats (Gaynor , 1997), sea lion pups (Heath et al, 1997), beavers (Breck and Gaynor, 2003), and ferrets (Lawson et al, 2006). Isoflurane is a volatile agent with a low blood:gas solubility coefficient (1.4 versus 2.4 for halothane) and low tissue solubility, resulting in extremely rapid induction and recovery (Calvey and Williams, 2001).…”
Section: Discussionsupporting
confidence: 55%
“…Nevertheless, because we used this vaporizer outside its recommended range of temperatures (15 C to 35 C), the reported settings of isoflurane are not necessary equal to the actual concentration delivered. Even though isoflurane has a slightly pungent and ethereal odor and can irritate the upper airways (Calvey and Williams, 2001), martens tolerated induction via face mask well; this is consistent with observations of Siberian polecats (Gaynor , 1997), sea lion pups (Heath et al, 1997), beavers (Breck and Gaynor, 2003), and ferrets (Lawson et al, 2006). Isoflurane is a volatile agent with a low blood:gas solubility coefficient (1.4 versus 2.4 for halothane) and low tissue solubility, resulting in extremely rapid induction and recovery (Calvey and Williams, 2001).…”
Section: Discussionsupporting
confidence: 55%
“…1998; Polis et al. 2001), beaver (Breck & Gaynor 2003), goats (Hikasa et al. 2002) and humans (Ebert et al.…”
Section: Discussionmentioning
confidence: 99%
“…Portable anesthesia machines with isoflurane-specific vaporizers have been used in beavers (Castor canadensis; Breck and Gaynor 2003) and big brown bats (Eptesicus fuscus; Wimsatt et al 2005). However, these animals were easily and quickly transported to central processing facilities which facilitated the use of vaporizers.…”
mentioning
confidence: 99%