2013
DOI: 10.1259/bjr.20120238
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of iodinated contrast media for the assessment of atherosclerotic plaque attenuation values by CT coronary angiography: observations in anex vivomodel

Abstract: Objective: To compare the influence of different iodinated contrast media with several dilutions on plaque attenuation in an ex vivo coronary model studied by multislice CT coronary angiography. Methods: In six ex vivo left anterior descending coronary arteries immersed in oil, CT (slices/collimation 6460.625 mm, temporal resolution 210 ms, pitch 0.2) was performed after intracoronary injection of a saline solution, and solutions of a dimeric isosmolar contrast medium (Iodixanol 320 mgI ml 21) and a monomeric … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(11 citation statements)
references
References 34 publications
0
11
0
Order By: Relevance
“…Nonetheless, the contrast enhancement of EAT may be influenced by contrast media choice and individual factors such as ejection fraction. 24,25 According to literature, the time processing of EAT volume extracted from image data sets is small. [8][9][10][11][12][13] The distribution of EAT is not symmetrical and uniform, and it is prevalent at grooved segments for both data sets 1,26 ( Figures 6 and 7).…”
Section: Discussionmentioning
confidence: 99%
“…Nonetheless, the contrast enhancement of EAT may be influenced by contrast media choice and individual factors such as ejection fraction. 24,25 According to literature, the time processing of EAT volume extracted from image data sets is small. [8][9][10][11][12][13] The distribution of EAT is not symmetrical and uniform, and it is prevalent at grooved segments for both data sets 1,26 ( Figures 6 and 7).…”
Section: Discussionmentioning
confidence: 99%
“…Iodixanol solutions containing 40, 64, 80, and 160 milligram iodine (mgI) in 10 mL volume showed HU values of 122 ± 6.7, 200.6 ± 6.5, 259.7 ± 6.2, and 473.7 ± 7.3, respectively. Different dilutions of iomeprol containing 50, 80, 100, and 200 mgI in 10 mL volume showed 142.5 ± 8.5, 230.2 ± 7.8, 339.6 ± 7, and 559.8 ± 8.2 HU, respectively . Therefore, compounds having attenuation in these ranges were found to be visible under fluoroscopy and can be used for imaging applications.…”
Section: Resultsmentioning
confidence: 95%
“…The mean heart rate changes observed after intravenous CM injection were generally low without significant differences between the two contrast agents (31). Moreover, differently iodinated CMs demonstrated analogous effect on the attenuation profiles of a plaque, thus different CMs could be similarly used for the delineation of coronary atherosclerotic plaques (32).…”
Section: Chest Ct Tailored Protocolsmentioning