2002
DOI: 10.1016/s0002-9149(02)02257-9
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of impedance cardiography with invasive hemodynamic measurements in patients with heart failure secondary to ischemic or nonischemic cardiomyopathy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

7
79
0
5

Year Published

2004
2004
2013
2013

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 122 publications
(91 citation statements)
references
References 5 publications
7
79
0
5
Order By: Relevance
“…Secondly, the previous study was not placebocontrolled for PD 123319 infusion, which may have resulted in time effects on blood pressure. Finally, the population in the previous study were younger (18)(19)(20)(21)(22)(23)(24)(25)(26)(27)(28)(29)(30)(31) years, compared with 18-55 years in the present study).…”
Section: Parametersupporting
confidence: 43%
See 1 more Smart Citation
“…Secondly, the previous study was not placebocontrolled for PD 123319 infusion, which may have resulted in time effects on blood pressure. Finally, the population in the previous study were younger (18)(19)(20)(21)(22)(23)(24)(25)(26)(27)(28)(29)(30)(31) years, compared with 18-55 years in the present study).…”
Section: Parametersupporting
confidence: 43%
“…The accuracy and reproducibility of this device has been investigated and validated. [16][17][18][19][20] For both arterial stiffness and haemodynamic parameters, baseline recordings were measured at one-minute intervals for a total of 5 minutes. Values were averaged to give a mean baseline result.…”
Section: Methodsmentioning
confidence: 99%
“…However, only 14 patients (7%) in the safety analysis population had tricuspid valvular disorders that may have been associated with severe tricuspid regurgitation reported in their medical history. Furthermore, the thermodilution technique, which strongly correlates with the Fick oxygen technique, 28 was consistently used to measure cardiac output at baseline and after 16 weeks of study drug therapy. We cannot exclude the possibility that the pulmonary vasodilator effect of riociguat was accompanied by the development of ventilation/perfusion mismatching and that some of the increase in cardiac index observed in patients receiving riociguat occurred to mitigate that effect and to maintain peripheral oxygen delivery.…”
Section: C Cardiac Index (Ci) D Stroke Volume Index (Svi) E Pulmmentioning
confidence: 99%
“…Mede alterações instantâneas, batimento a batimento, da impedância eléctrica e, através de algoritmos, infere parâmetros como o volume sistólico, o débito cardíaco e o fl uido torácico total (FTT), entre outros. A última geração de aparelhos de BET tem vindo a ganhar relevo, com estudos comprovando a sua efi cácia em várias patologias e correlação com determinações invasivas [7][8][9] . O FTT, um novo parâmetro avaliado de forma não invasiva por BET, é um indicador do volume total de fl uidos no tórax, tanto intra como extracelulares, em particular a nível do pulmão 10 .…”
Section: Introductionunclassified